background image

If you cannot find a solution...

If you cannot find a solution to the problem

yourself, contact your dealer or an Authorised

Service Centre. Give the data from the rating

plate. Make sure, you operated the hob

correctly. If not the servicing by a service

technician or dealer will not be free of charge,

also during the warranty period. The instructions

about the Service Centre and conditions of

guarantee are in the guarantee booklet.

Labels supplied with the accessories

bag

Stick the adhesive labels as indicated below:

MOD.

PROD.NO.

SER.NO

DATA

MOD.

PROD.NO.

SER.NO

DATA

MOD.

PROD.NO.

SER.NO.

03   IT

MADE IN ITALY

TYPE

IP20

0049

A

B

C

A) Stick it on Guarantee Card and send this

part (if applicable).

B) Stick it on Guarantee Card and keep this

part (if applicable).

C) Stick it on instruction booklet.

Installation

WARNING!

Refer to Safety chapters.

Before the installation

Before you install the hob, write down the

information bellow from the rating plate. The

rating plate is on the bottom of the hob.

Model .......................................

PNC .........................................

Serial number ...........................

Important safety requirements

This hob must be installed in accordance with

the Gas Safety (Installation and Use)

Regulations (Current Edition) and the IEE

Wiring Regulations (Current Edition).

For appliances installed in the Republic of

Ireland please refer to NSAI- Domestic Gas

Installation I.S. 813 Current Editions and the

ETCI Rules for Electrical Installations.
Provision for ventilation

Detailed recommendations are contained in the

following British Standards Codes Of Practice:

B.S. 6172/B.S. 5440, Par. 2 and B.S. 6891

Current Editions.
The hob should not be installed in a bed sitting

room with a volume of less than 20 m³. If it is

installed in a room of volume less than 5 m³ an

air vent of effective area of 100 cm² is required.

If it is installed in a room of volume between 5

m³ and 10 m³ an air vent of effective area of 50

cm² is required, while if the volume exceeds 11

m³ no air vent is required.

www.zanussi.com

9

Содержание ZGH62414XS

Страница 1: ...EN ZGG67412 User Manual GB ...

Страница 2: ...cal sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not let children play with the appliance Keep all packaging away from children Keep children and pets away from the appliance when it operates or when it cools down Accessible parts are hot If ...

Страница 3: ...e room temperature Safety instructions This appliance is suitable for the following markets GB Installation WARNING Only a qualified person must install this appliance Remove all the packaging Do not install or use a damaged appliance Obey the installation instruction supplied with the appliance Keep the minimum distance from the other appliances and units Always be careful when you move the appli...

Страница 4: ...contact opening width of minimum 3 mm Gas connection All gas connections should be made by a qualified person Before installation make sure that the local distribution conditions nature of the gas and gas pressure and the adjustment of the appliance are compatible Make sure that there is air circulation around the appliance The information about the gas supply is on the rating plate This appliance...

Страница 5: ...rposes only It must not be used for other purposes for example room heating Do not let acid liquids for example vinegar lemon juice or limescale remover touch the hob This can cause matt patches Care and cleaning Clean regularly the appliance to prevent the deterioration of the surface material Deactivate the appliance and let it cool down before you clean it Disconnect the appliance from the elec...

Страница 6: ... or less than 10 seconds this will let thermocouple to warm up If not the gas supply will be interrupted 4 Adjust the flame after it is regular If after some tries the burner does not light check if the crown and its cap are in correct positions WARNING Do not keep the control knob pushed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into o...

Страница 7: ...lame heats the control knob up CAUTION Make sure that pot handles are not above the front edge of the cooktop CAUTION Make sure that the pots are placed centrally on the burner in order to get maximum stability and to get lower gas consumption Diameters of cookware Use cookware with diameters applicable to the size of burners Burner Diameter of cookware mm Rapid 180 260 Semi rapid 120 220 Auxiliar...

Страница 8: ...ic ignition candle with a metal electrode Keep these components well clean to prevent difficult lighting and check that the burner crown holes are not obstructed Periodic maintenance Speak to your local Authorised Service Centre periodically to check the conditions of the gas supply pipe and the pressure adjuster if fitted Troubleshooting WARNING Refer to Safety chapters What to do if Problem Poss...

Страница 9: ...e you install the hob write down the information bellow from the rating plate The rating plate is on the bottom of the hob Model PNC Serial number Important safety requirements This hob must be installed in accordance with the Gas Safety Installation and Use Regulations Current Edition and the IEE Wiring Regulations Current Edition For appliances installed in the Republic of Ireland please refer t...

Страница 10: ...in this instruction booklet be ignored On the end of the shaft which includes the G 1 2 threaded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force A B C A End of shaft with nut B Washer C Elbow Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The...

Страница 11: ...up to a temperature of more than 90 C The cable should be guided by means of clamps fixed to the side of the cabinet in order to avoid any contact with the equipment beneath the cooktop Make sure that there is access to the mains plug after the installation Electrical Requirements Permanent electrical installation must agree with the latest I E E Regulations and local Electricity Board regulations...

Страница 12: ...type Make sure that the cable section is applicable to the voltage load and the working temperature The yellow green earth wire B must be approximately 2 cm longer than the live and neutral wire A A B 1 Connect the green and yellow earth wire to the terminal which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue neutral wire to the terminal which is m...

Страница 13: ...ccess in case a technical assistance intervention is necessary Kitchen unit with door min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit Technical information Hob dimensions Width 580 mm Depth 500 mm www zanus...

Страница 14: ...amp cartridge fuse Appliance category II2H3 Gas connection R 1 2 Appliance class 3 Gas burners for NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK 1 100 mm Rapid 3 0 0 75 119 Semi rapid 2 0 0 45 96 Auxiliary 1 0 0 33 70 Gas burners for LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK 1 100 mm NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mb...

Страница 15: ...e cookware with diameters applicable to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refer to its user manual ENVIRONMENT CONCERNS Recycle the materials with the symbol Pu...

Страница 16: ...www zanussi com shop 867321555 A 212015 ...

Отзывы: