OTHER TECHNICAL DATA
TOTAL POW-
ER:
Gas original:
G20 (2H) 20 mbar
11,65 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar
832 g/h
G31 (3+) 37 mbar
818 g/h
Electric supply:
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse
Appliance cate-
gory:
II2H3+
Gas connec-
tion:
R 1/2"
Appliance
class:
3
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER kW
INJECTOR MARK
Multi Crown
4,0
1,4
146
Rapid
2,95
0,75
119°
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
WARNING! This appliance does not
function with the existing gas settings
if installed in Malta. Therefore, before
connecting the appliance it is essential
to change the nozzles according to the
type of gas used according to the
table below.
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar
G31 37 mbar
Multi Crown
3,65
1,4
095
265
261
Rapid
2,8
0,95
86
204
200
Semi-rapid
2,0
0,6
71
145
143
Auxiliary
1,0
0,33
50
73
71
16