BYPASS DIAMETERS
BURNER
Ø BYPASS 1/100 mm
Triple Crown
57
Semi-rapid
32
Auxiliary
28
OTHER TECHNICAL DATA
TOTAL POW-
ER:
Gas original:
G20 (2H) 20 mbar
9 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar
G31 (3+) 37 mbar
654 g/h
643 g/h
Electric supply:
220-240 V ~ 50/60 Hz
Appliance cate-
gory:
II2H3+
Gas connec-
tion:
R 1/2"
Appliance
class:
3
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER kW
INJECTOR MARK
Triple Crown
4,0
1,4
146
Semi-rapid
2,0
0,45
96
Auxiliary
1,0
0,33
70
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar
G31 37 mbar
Triple
Crown
4,0
1,4
98
291
286
Semi-rapid
2,0
0,45
71
145
143
Auxiliary
1,0
0,33
50
73
71
14