background image

BYPASS DIAMETERS

BURNER

Ø BYPASS 1/100 mm

Triple Crown

57

Semi-rapid

32

Auxiliary

28

OTHER TECHNICAL DATA

TOTAL POW-

ER:

Gas original:

G20 (2H) 20 mbar

9 kW

Gas replace-

ment:

G30 (3+) 28-30 mbar

G31 (3+) 37 mbar

654 g/h

643 g/h

Electric supply:

220-240 V ~ 50/60 Hz

Appliance cate-

gory:

II2H3+

Gas connec-

tion:

R 1/2"

Appliance

class:

3

GAS BURNERS FOR NATURAL GAS G20 20 mbar

BURNER

NORMAL POWER kW MINIMUM POWER kW

INJECTOR MARK

Triple Crown

4,0

1,4

146

Semi-rapid

2,0

0,45

96

Auxiliary

1,0

0,33

70

GAS BURNERS FOR LPG G30/G31 28-30/37 mbar

BURNER

NORMAL

POWER kW

MINIMUM

POWER kW

INJECTOR

MARK

NOMINAL GAS FLOW g/h

G30 28-30 mbar

G31 37 mbar

Triple

Crown

4,0

1,4

98

291

286

Semi-rapid

2,0

0,45

71

145

143

Auxiliary

1,0

0,33

50

73

71

14

Содержание ZGG66424XA

Страница 1: ...GETTING STARTED EASY User Manual ZGG66424XA EN User Manual Hob EG ...

Страница 2: ...sons with very extensive and complex disabilities shall be kept away unless continuously supervised Children of less than 3 years of age should be kept away unless continuously supervised Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible p...

Страница 3: ... you route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temperatures of more than 50 C above room temperature WARNING Use only hob guards designed by the manufacturer of the cooking appliance or indicated by the manufacturer of the appliance in the instructions for use as suitable or hob guards incorporate...

Страница 4: ... plug after the installation If the mains socket is loose do not connect the mains plug Do not pull the mains cable to disconnect the appliance Always pull the mains plug Use only correct isolation devices line protecting cut outs fuses screw type fuses removed from the holder earth leakage trips and contactors The electrical installation must have an isolation device which lets you disconnect the...

Страница 5: ...ample vinegar lemon juice or limescale remover touch the hob This can cause matt patches Discoloration of the enamel or stainless steel has no effect on the performance of the appliance CARE AND CLEANING WARNING Do not remove the buttons knobs or gaskets from the control panel Water may get inside the appliance and cause damage Clean the appliance regularly to prevent the deterioration of the surf...

Страница 6: ...but shows its correct elasticity the fastening clamps are not rusted expired term is not due If one or more defects are visible do not repair the pipe but replace it WARNING When installation is complete make sure that the seal of each pipe fitting is correct Use a soapy solution not a flame INJECTORS REPLACEMENT 1 Remove the pan supports 2 Remove the caps and crowns of the burner 3 With a socket ...

Страница 7: ...connection with an extension cable an adapter or a multiple connection Make sure that the ground connection agrees with the standards and regulations Do not let the power cable to heat up to a temperature higher than 90 C Make sure that you connect the blue neutral cable to the terminal with a letter N on it Connect the brown or black phase cable to the terminal which has a letter L Keep the phase...

Страница 8: ...he hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary Kitchen unit with door min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit 8 ...

Страница 9: ... Semi rapid burner 2 Triple Crown burner 3 Auxiliary burner 4 Control knobs CONTROL KNOB Symbol Description no gas supply off position ignition position maximum gas supply Symbol Description minimum gas supply DAILY USE WARNING Refer to Safety chapters 9 ...

Страница 10: ...shed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity you can ignite the burner without electrical device in this case approach the burner with a flame turn the control knob counter clockwise to maximum gas supply position and push ...

Страница 11: ...IAMETERS OF COOKWARE Use cookware with diameters applicable to the size of burners Burner Diameter of cook ware mm Triple Crown 180 260 Semi rapid front 120 180 Semi rapid rear 120 220 Auxiliary 80 160 CARE AND CLEANING WARNING Refer to Safety chapters GENERAL INFORMATION Clean the hob after each use Always use cookware with a clean base Scratches or dark stains on the surface have no effect on ho...

Страница 12: ...hem carefully before you put them back on CLEANING THE SPARK PLUG This feature is obtained through a ceramic ignition candle with a metal electrode Keep these components well clean to prevent difficult lighting and check that the burner crown holes are not obstructed PERIODIC MAINTENANCE Speak to your local Authorised Service Centre periodically to check the conditions of the gas supply pipe and t...

Страница 13: ...g by a service technician or dealer will not be free of charge also during the warranty period The instructions about the Service Centre and conditions of guarantee are in the guarantee booklet LABELS SUPPLIED WITH THE ACCESSORIES BAG Stick the adhesive labels as indicated below MOD PROD NO SER NO DATA MOD PROD NO SER NO DATA MOD PROD NO SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it o...

Страница 14: ...ce cate gory II2H3 Gas connec tion R 1 2 Appliance class 3 GAS BURNERS FOR NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Triple Crown 4 0 1 4 146 Semi rapid 2 0 0 45 96 Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Triple Crown 4 0 1 4 98 291 286 S...

Страница 15: ...tainers to recycle it Help protect the environment and human health by recycling waste of electrical and electronic appliances Do not dispose of appliances marked with the symbol with the household waste Return the product to your local recycling facility or contact your municipal office 15 ...

Страница 16: ...WWW ZANUSSI COM SHOP 867329568 C 392018 ...

Отзывы: