10
Cut Out Size
The dimensions of the cut-out are given in the diagram.
550
47
0
30
Rectangular cut-out size for hob
Dimensions are given in mm.
FO 2038
FO 2098
ZGG 642
ZGG 782
A)
End of shaft with nut
B)
Washer
C)
Elbow
FO 0814
FO 0264
Installation
IMPORTANT
This hob must be installed by a
competent
person
to the relevant Gas Standards.
Any gas installation must be carried out by a
registered competent person.
The manufacturer will not accept liability, should
the above instructions or any of the other safety
instructions incorporated in this book be
ignored.
Gas Connection
Connection to the gas supply should be with either rigid
or semi-rigid pipe, i.e. steel or copper.
The connection should be suitable for connecting to RC
1/2 (1/2 BSP male thread).
When the final connection has been made, it is essential
that a thorough leak test is carried out on the hob and
installation. Ensure that the main connection pipe does
not exert any strain on the hob.
It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to the
hob connecting pipe.
Failure to ensure the correct assembly will cause
leakage of gas.
WHEN THE HOB IS FIRST INSTALLED
Once the hob has been installed, it is important
to remove any protective materials, which were
put on in the factory.
On the end of the shaft, which includes the GJ 1/2"
threaded elbow, adjustment is fixed so that the washer
is fitted between the components as shown in the
diagram. Screw the parts together without using excessive
force.
Содержание ZGG 782
Страница 18: ...18 ...
Страница 19: ...19 ...
Страница 20: ...Grafiche MDM Forlì 35668 9204 11 06 www zanussi electrolux co uk ...