manualshive.com logo in svg
background image

6

Technical Data

Gas Burners Rating

Double crown Burner

3,5  kW

Rapid Burner (big)

3 kW (G20) - 2,8 kW (G30-31)

Auxiliary Burner (small)

1  kW

Semirapid Burner (medium)

2  kW

Class 3 Appliance
Category

II 2E+3+

Setting

Natural Gas G20/ G25 - 20/25 mbar

Gas connection

G 1/2"

Electric Supply

230 V  50 Hz

HOB RECESS
DIMENSIONS

Length

560 mm.

Width

480 mm.

Instruction for the Installer

The following instructions about installation and
maintenance must be carried out by qualified
personnel in compliance with the regulation in
force. The regulation to be applied for this type of
installation is NBN D 5I.003 : "Installations
functioning with combustible gas lighter than
air".

The appliance must be electrically disconnected
before all interventions. If any electric supply to
the appliance is required to carry out the work,
ensure all the necessary precautions are
followed.

The side walls of the unit in which the hob is
going to be installed, must not exceed the height
of the working top.

Avoid installing the appliance in the proximity of
inflammable materials (e.g. curtains, tea towels
etc.).

GAS CONNECTION

It is indispensible that the connection to the gas mains
are carried out by means of an AGB tap. Choose fixed
connections or use a flexible pipe in AGB (stainless
steel).
If using flexible metallic pipes, be careful they do not
come in contact with mobile parts or they are not
squeezed. Use the same attention when the hob is
combinated with an oven.

This hob can be operated by Slochteren gas (G25) with
a nominal pressure of 25 mbar or by natural gas with
nominal pressure of 20 mbar. No regulation is required
for use by these two types of gas.

Before fitting the appliance ensure that the installation
has the correct  voltage for the appliance. At full capacity,
the drop in pressure must not exceed 5%. Such a drop
in pressure is caused by the following parameters:

- maximum capacity of meter;

- diameter and lenght of the tube in front and behind

the meter;

- section of transit of variuos tubes positioned on the

circuit;

- diameter of eventual connections.

IMPORTANT  - 

 To ensure a correct operation, a saving

of energy and the long-life of the appliance, the voltage
pressure of the appliance must correspond to the
recommended values.

The adjustable connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2". Interpose the
sealing between the components as shown in Fig. 4.
Screw the parts without forcing, adjust the connection in
the required direction and tighten everything.

IMPORTANT

 - When the final connection has been

made, it is essential that a thorough leak test is carried
out on the hob and installation. Use some soapy water,

never a flame.

A) Ramp with ending nut
B) Seal
C) Adjustable connection

Fig. 4

FO 2365

Содержание ZGF 783

Страница 1: ...INSTRUCTION BOOKLET P OBOƒCTBO œO CœÀ ATA RU GAS HOB A OBAfl BAPO HAfl œOBEPXHOCT ZGF 753 ZGF 783 GB ...

Страница 2: ...2 ...

Страница 3: ...odifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor air supp...

Страница 4: ... flame out turn the knob to the symbol In the absence of electricity ignition can occur without the electrical device in this case approach the burner with a flame push the relevant knob down and turn it anti clockwise until it reaches the maximum position Always turn the flame down or put it out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it i...

Страница 5: ... shown in Fig 2 To take the pan supports completely off the hob proceed as shown in Fig 3 Fig 2 Fig 3 FO 2030 FO 2238 THE HOB LID In order to make the appliance match with the kitchen design a lid not provided can be fitted on the hob The lid is meant to avoid dust to settle on the hob when it is closed and to collect splashes of oil or fat when it is open Do not use it for any other purpose Alway...

Страница 6: ...f using flexible metallic pipes be careful they do not come in contact with mobile parts or they are not squeezed Use the same attention when the hob is combinated with an oven This hob can be operated by Slochteren gas G25 with a nominal pressure of 25 mbar or by natural gas with nominal pressure of 20 mbar No regulation is required for use by these two types of gas Before fitting the appliance e...

Страница 7: ...iance and the electricity supply with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnec...

Страница 8: ...ers proceed as follows Light the burner Turn the knob on the minimum position Remove the knob With a thin screwdriver adjust the by pass screw see Fig 8 If changing from natural gas to LPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quickly turning the knob from the maximum position to the minimum position This procedu...

Страница 9: ...nd the hob Fig 10 c Fit the left hand lid hinge marked S into the hinge block Fig 11 d Carry out the same operation with the right hand lid hinge marked D ADJUSTING THE LID BALANCE To adjust the lid balance turn clockwise or anti clockwise the central screw of the right and left hand hinges Fig 12 BuildingIn A Auxiliary burner SR Semirapid burner R Rapid Burner UR Double crown burner These hobs ca...

Страница 10: ...ob as follows put the relevant sealings supplied with the hob on the edges of the cut out place them at 8 mm from the front and rear edge and at 50 mm from the side edges as shown in Fig 14 taking care that the sealings meet without overlapping placethehobinthecutout takingcareofitscentring fix the hob with the relevant screws Fig 15 The traction of the screws is able to trace the sealing any exce...

Страница 11: ...s to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 18 e 19 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off the unit Hanging forniture units or hoods must be placed at 650 mm minimum from the hob Fig 21 In case a hood with lenght of 600 m...

Страница 12: ...es carried out by people who are not qualified or expert or defects that result from the addition of DECLARATION OF GUARANTEE TERMS BELGIUM non original accessories or spare parts are not covered by the guarantee 10 Appliances that are easy to transport may be delivered or sent to the consumer services department Home repairs are only anticipated for bulky appliances or built in appliances 11 If t...

Отзывы: