OVERALL DIMENSIONS
Width:
680 mm
Depth:
510 mm
CUT OUT DIMENSIONS
Width:
560 mm
Depth:
480 mm
SUPPLY CONNECTIONS
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Rear Left Burner (semi rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Left Burner (auxiliary)
Heat Input
1.0 kW (3413 BTU/HR)
Rear Right Burner (semi rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Right Burner (rapid)
Heat Input
3.0 kW (10236 BTU/HR)
Central Burner (Ultra-rapid Triple-crown)
Heat Input
4.0 kW (13652 BTU/HR)
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Ultra-rapid
56
Aeration adjustment none
Instructions for the Installer
Engineers technical data
APPLIANCE CLASS
: 3
APPLIANCE CATEGORY
: II2H3+
APPLIANCE GAS SUPPLY
: Natural gas G20 / 20mbar
BURNER
RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.0
0.65
2.0
0.45
1.0
0.33
4.0
1.2
NOMINAL FLOW
RATE m
3
/h
0.286
0.062
0.190
0.043
0.095
0.031
0.381
0.114
NOZZLE REFERENCE
119
Adjust.
96
Adjust.
70
Adjust.
146
Adjust.
NOMINAL THERMAL
POWER kW
2.8
0.65
2.0
0.45
1.0
0.33
4.0
1.2
NOMINAL FLOW
RATE g/h
202
47
144
32
72
24
288
86
NOZZLE REFERENCE
86
40
71
32
50
28
98
56
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
ULTRA-RAPID