Zanussi ZGF 6420 Скачать руководство пользователя страница 9

9

Important safety requirements

650 mm

400 mm

400 mm

100 mm

50 mm

50 mm

55 mm

600 mm

700 mm

400 mm

100 mm

400 mm

50 mm

55 mm

50 mm

I

CLEARANCES REQUIRED

 WHEN FITTING THE HOB

WITHOUT A COOKER HOOD ABOVE

CLEARANCES REQUIRED

WHEN FITTING THE HOB

WITH A COOKER HOOD ABOVE

FO 0813

FO 0812

700 mm

This hob must be installed in accordance with the Gas
Safety (Installation and Use) Regulations (Current Edition)
and the IEE Wiring Regulations (Current Edition).
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813 Current
Editions and the ETCI Rules for Electrical Installations.

Provision for Ventilation

Detailed recommendations are contained in the following
British Standards Codes Of Practice: B.S. 6172/ B.S.
5440, Part 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed sitting room
with a volume of less than 20 m

3

. If it is installed in a

room of volume less than 5 m

3

 an air vent of effective

area of 110 cm

2

 is required. If it is installed in a room of

volume between 5 m

3

 and 10 m

3

 an air vent of effective

area of 50 cm

2

 is required, while if the volume exceeds

11 m

3

 no air vent is required.

However, if the room has a door which opens directly to
the outside no air vent is required even if the volume is
between 5 m

and 11 m

3

.

If there are other fuel burning appliances in the same
room, B.S. 5440 Part 2 Current Edition, should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland please
refer to the NSAI- Domestic Gas Installation I.S. 813
Current Editions Table Four.

Location

The hob may be located in a kitchen, a kitchen/diner or
bed sitting room, but not in a bathroom, shower room or
garage.
Before making the cut out in the worktop ensure that
there is a minimum distance of 55 mm between the rear
edge of the hob and the wall.
A minimum distance of 100 mm must be left between
the side edges of the hob and any adjacent cabinets or
walls.
The minimum distance combustible material can be fitted
above the hob in line with the edges of the hob is 400
mm. If it is fitted below 400 mm a space of 50 mm must
be allowed from the edges of the hob.
The minimum distance combustible material can be fitted
directly above the hob is 700 mm.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S 813 Current
Edition Section 7- Permitted Locations of Appliance.

Содержание ZGF 6420

Страница 1: ...GAS HOB ZGF 6420 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB ...

Страница 2: ...t with the hot surfaces of the cooking appliance Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage Never leave the hob unattended when cooking with oil and fats Never use plastic or aluminium foil dishes on the hob Perishable food plastic items and aerosols may be affected by heat and should not be stored above or below the hob u...

Страница 3: ...Information 2 Description of the Hob 3 Operation 4 Maintenance and Cleaning 4 Something Not Working 5 Service and Spare Parts 6 Customer Care 6 Guarantee Conditions 6 European Guarantee 7 Instructions for the Installer 8 Installation 10 Electrical Connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 1 3 2 3 4 5 ...

Страница 4: ...mmended size the flame will spread beyond the bottom of the vessel causing the handle to overheat Take care when frying food in hot oil or fat as the overheated splashes could easily ignite As soon as a liquid starts boiling turn down the flame so that it will barely keep the liquid simmering If the control knobs become difficult to turn please contact your local Service Force Centre Before any ma...

Страница 5: ...eaning be sure to wipe dry with a soft cloth Ignition Electrode The electric ignition is obtained through a ceramic electrode and a metal electrode Fig 1 letter C Keep these components very clean to avoid lighting difficulties and check that the burner crown holes are not obstructed YES NO Something Not Working If the hob is not working correctly please carry out the following checks before contac...

Страница 6: ...Mile Road Dublin 12 RepublicofIreland Tel 353 0 1 4090751 e mail service eid electrolux ie Zanussi Guarantee Conditions We Zanussi undertake that if within 24 months of the date of the purchase this Zanussi appliance or any part thereof is proved to be defective by any reason only of faulty workmanship or materials we will at our option repair or replace the same FREE OF ANY CHARGE for labour mate...

Страница 7: ...ller of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of residence for this particular model or range of appliances The appliance guarantee is personal to the original purchaser of the appliance and cannot be transferred to another user The appliance is installed and used in accordance with instructions issued...

Страница 8: ...MAX MIN MAX MIN NOMINALTHERMAL POWER kW 3 0 0 65 2 0 0 45 1 0 0 33 NOMINALFLOW RATE m3 h 0 286 0 062 0 190 0 043 0 095 0 031 NOZZLEREFERENCE 119 Adjust 96 Adjust 70 Adjust NOMINALTHERMAL POWER kW 2 8 0 65 2 0 0 45 1 0 0 33 NOMINALFLOW RATE g h 202 47 144 32 72 24 NOZZLEREFERENCE 86 40 71 32 50 28 Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Aerationadjustmentnone NATURAL GAS...

Страница 9: ...volume exceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements For appliances installed in the Republic of Ireland please...

Страница 10: ...T This hob must be installed by a competent person to the relevant Gas Standards Please ensure that once the hob is installed it is easily accessible for the engineer in the event of a breakdown WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed it is important to remove any protective materials which were put on in the factory Any gas installation must be carried out by a competent p...

Страница 11: ...le seal which prevents the ingress of liquids Dimensions are given in mm Building In Building over a Cupboard or Drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface Building over a Kitchen Unit with Door Proper arrangements must be taken in designing the furniture unit in o...

Страница 12: ...wn Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there mus...

Страница 13: ...hat the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evidence of burning around the fault START Isolate appliance and ...

Страница 14: ... burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insulation ...

Страница 15: ... hob Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting To do this follow the procedure below Turn the gas tap to the MAX position and ignite Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times If the flame is unstable or is extinguished follow the procedure below Procedure Re ignite the burner ...

Страница 16: ...Grafiche MDM Forlì 35687 8602 04 06 CUSTOMER CARE Zanussi Major Appliances Addington Way Luton Bedfordshire LU4 9QQ Electrolux plc 2003 www zanussi electrolux co uk ...