This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling). All cookers hood perform better when used
in evacuation mode. During winter time it may be convenient to use the hood in the recycling
mode to avoid heat loss from the kitchen.
Before starting the installation, consideration should be given to the difficulties to
be found during installation. The installation work must be undertaken by a qualified
and competent person in conformity to the rules concerning the evacuation of
contaminated air. The manufacturer disclaims all liability for any damage or injury
caused as a result of not following the instructions for installation contained in the
following text.
1-SAFETY WARNINGS
1.1 - When used in the extraction mode, the cooker hood ducting must not be connected
to a flue which is used for exhausting fumes from appliances supplied with energy other
than electric, such as a central heating flue or water heating flue.
1.2 - Before connecting to the mains supply ensure that the mains voltage corresponds
with the voltage on the rating plate inside the hood.
1.3 - Connect the cooker hood to the mains via a bipolar switch which has 3mm clearance
between the contacts.
1.4 - For cooker hoods featuring an earth cable, make sure the electric plant of your
house is cor-rectly earthed.
1.5 - Appliance in class II are provided with a double insulation; therefore do not connect
then hrough earthed plugs but through simple bipolar plugs.
1.6 - When installed, the hood must be positioned at least 65cm above the hotplate.
1.7 - Never do flambé cooking under this cooker hood.
1.8 - Never leave frying pans unattended during use as overheated fat and oil may catch
fire.
1.9 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from
the mains supply.
1.10 - If the room where the cooker hood is to be used contains a fuel burning appliance
such as acentral heating boiler then this must be of the room sealed or balanced flue
type. If other types of flue or appliance are fitted, ensure that there is an adequate supply
of air into the room. When the cooker hood is used in conjunction with appliances supplied
with energy other than electric, the negative pressure in the room must not exceed 0,04
mbar to prevent fumes being drawn back into the room by the cooker hood.
2-INSTALLATION INSTRUCTIONS
Some installation systems require the opening and removal of the metal grille panel.
2.1-Instructions for opening and removing the metal grille panel
To open the grille panel, press inwardly on the two slider catches at each side of the grille
panel and the grille will pivot down.
To remove the metal grille, pull forward on the right hand side so that the hinge pin on the
back of the grille will be released from the slot in the side of the casing.