Natural Gas:
G20 (2H) 20 mbar
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Auxiliary
29 / 30
Semi-rapid
32
Rapid
42
Triple Crown
67
Oven
54
Grill
59
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
REDUCED POWER kW
INJECTOR MARK
1/100 mm
Triple Crown
4.0
1.8
146
Rapid
3.0
0.72
119
Semi-rapid
2.0
0.43
96
Auxiliary
1.0
0.35
70
Oven
3.9
1.5
136
Grill
3.0
1.6
126
Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL POWER
kW
REDUCED POWER kW
INJECTOR MARK
1/100 mm
Triple Crown
4.0
1.8
101
Rapid
3.0
0.72
88
Semi-rapid
2.0
0.43
71
Auxiliary
1.0
0.35
50
Oven
3.9
1.5
95
Grill
3.0
1.6
88
Gas connection
The gas pipe in the appliance has two endings.
You can connect the gas supply to either one of
them. The pipe that is not used must be
clogged with the pipe closer, which added to
the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
www.zanussi.com
21
Содержание ZCG91206
Страница 1: ...EN ZCG91206 ZCG91226 ZCG92226 User Manual Cooker EG JO LY MA SD TN ...
Страница 27: ...www zanussi com 27 ...
Страница 28: ...www zanussi com shop 867306279 C 332016 ...