Zanussi ZAF2 Скачать руководство пользователя страница 5

33

4. Instruction for the Installer

The side walls of the unit in which the hob is
going to be installed, must not exceed the height
of the working top.

Avoid installing the appliance in the proximity of
inflammable materials (e.g. curtains, tea towels
etc.).

The following instructions about installation and
maintenance must be carried out by qualified
personnel in compliance with the regulation in
force. The regulation to be applied for this type of
installation is NBN D 5I.003 : "Installations
functioning with combustible gas lighter than
air".

The appliance must be electrically disconnected
before all interventions. If any electric supply to
the appliance is required to carry out the work,
ensure all the necessary precautions are
followed.

GAS CONNECTION

It is indispensible that the connection to the gas mains
are carried out by means of an AGB tap. Choose fixed
connections or use a flexible pipe in AGB (stainless
steel).
If using flexible metallic pipes, be careful they do not
come in contact with mobile parts or they are not
squeezed. Use the same attention when the hob is
combinated with an oven.

This hob can be operated by Slochteren gas (G25) with
a nominal pressure of 25 mbar or by natural gas with
nominal pressure of 20 mbar. No regulation is required
for use by these two types of gas.

Before fitting the appliance ensure that the installation
has the correct  voltage for the appliance. At full capacity,
the drop in pressure must not exceed 5%. Such a drop
in pressure is caused by the following parameters:

-

maximum capacity of meter;

-

diameter and lenght of the tube in front and behind
the meter;

-

section of transit of variuos tubes positioned on the
circuit;

-

diameter of eventual connections.

IMPORTANT  -  To ensure a correct operation, a saving
of energy and the long-life of the appliance, the voltage
pressure of the appliance must correspond to the
recommended values.

The adjustable connection is fixed to the comprehensive
ramp by means of a threaded nut GJ 1/2". Interpose the
sealing between the components as shown in fig. 3.
Screw the parts without forcing, adjust the connection in
the required direction and tighten everything.
The adjustable connection allows the feeding pipe to be
situated in the site purposefully allocated on the side of
the protection box of the hob itself (Fig. 4). This connection
allows the overall dimensions of the hob plus the fedding
pipe to be contained into a depth of 30 mm.

IMPORTANT - When the final connection has been
made, it is essential that a thorough leak test is carried
out on the hob and installation. Use some soapy water,
never a flame.

A) Ramp with ending nut
B) Seal
C) Adjustable connection

Fig. 3

FO 0264

Fig. 4

A) Ramp ending with nut
B) Adjustable connection
C) Rigid or flexible metallic gas pipe

FO 0265

Содержание ZAF2

Страница 1: ...MODE D EMPLOI GEBRUIKSAANWIJZING BEDIENUNGSANWEISUNGEN INSTRUCTIONS FOR USE TABLES DE CUISSON KOOKPLATEN KOCHMULDEN HOBS ZAF 2 ...

Страница 2: ...quent modifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor a...

Страница 3: ...t out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the table beside It is also advisable as soon as a liquid starts boiling to turn down the flame so that it will barely ke...

Страница 4: ...th a soft cloth The pan supports are dishwasher proof If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids In models provided with electric ignition this feature is obtained through a ceramic candle and a metal electrode fig 1 lett C Keep these components well clean to avoid difficult lighting and check that the ...

Страница 5: ...use by these two types of gas Before fitting the appliance ensure that the installation hasthecorrect voltagefortheappliance Atfullcapacity the drop in pressure must not exceed 5 Such a drop in pressure is caused by the following parameters maximum capacity of meter diameter and lenght of the tube in front and behind the meter section of transit of variuos tubes positioned on the circuit diameter ...

Страница 6: ...ance and the electricity supply with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnect...

Страница 7: ...T OF MINIMUM LEVEL To adjust the minimum level of the burners proceed as follows Light the burner Turn the knob on the minimum position Remove the knob With a thin screwdriver adjust the by pass screw seeFig 8 a IfchangingfromnaturalgastoLPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quickly turning the knob from the ...

Страница 8: ...ithout overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 11 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids If several function are to be combined 2 burners hob fish kett...

Страница 9: ...ion given in Figs 13 and 16 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 14 and 15 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off the unit Hanging forniture units or hoods must be placed at 650 mm ...

Отзывы: