background image

9

OVERALL  DIMENSIONS

Width:

580 mm.

Depth:

510 mm.

Height:

84 mm.

Weight:

11 Kg.

CUT  OUT  DIMENSIONS

Width:

560 mm.

Depth:

480 mm.

Thickness: 30 mm.

Instructions  for  the  Installer

Engineer technical data

Supply Connections

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230 V 50Hz supply, 3 core flexible cable with non

rewireable plug.

Appliance Gas supply

: LPG 30 mbar

Appliance Class

: 3

Appliance category

: I 3

Burner

              Nominal Power      LPG (Butane "A")   Diameter

Feeding

  Tap. By-Pass

Pressure

kW

kCal/h

Nozzle

g/h

mbar (*)

Auxiliary (dia. 42 mm.)

0,95

814

50

75

  28

Semi-rapid (dia. 57 mm.)

1,60

1368

65

126

  35

30

Powered Rapid (dia. 90 mm.)

2,9

2475

85

228

  45

(*) 1 mbar = 10 mm. water coloumn.

Содержание PW64

Страница 1: ... Procedure Re ignite the burner and set to MIN Removethecontrolknob insertathin bladedscrewdriverdowntheholeinthe frontpanelandturntheadjustmentscrew untiltheflameissteadyanddoesnot extinguish whentheknobisturnedfrom MIN to MAX Repeat this procedure for all burners F Technical Maintenance Checkatregularintervalstheconditionand serviceabilityofthegasconnectionhoseandpressure regulator if any is fit...

Страница 2: ...onnectioncanbeeasilyreachedwith the appliance built in the forniture unit Before switching on make sure the electricity supply voltageisthesameasthatindicatedontheappliance ratingplate Theratingplateislocatedonthebottom of the hob Acopy is attachedonthebackcoverof thisbook The appliance is supplied with a 3 core flexible supplycordincorporatingaplug Connecttheplugto anadequatesocket Permanent Conn...

Страница 3: ...aking care that the seals meet without overlapping placethehobinthecutout takingcarethatit iscentred fix the hob with the relevant fixing clamps andscrews asshowninthediagram When thescrewshavebeentightened theexcess sealcanberemoved Theedgeofthehobformsadoublesealwhich preventstheingressofliquids Seal F Fitting the hob to the worktop FO2239 ...

Страница 4: ...calassistance isneeded Thespacebehindthekitchenunit b can beusedforconnections a Removablepanel b Roomforconnections 550 min 560 min FO0198 Building over a kitchen unit with oven If the hob is built into a kitchen unit with an oven underneath therecessmusthavethedimensions shownindiagrams2and3 andshouldalsoincorpo ratesuitableovencrosspiecesupportstoensurean efficient cooling air circulation Diagr...

Страница 5: ...n the end of the shaft A which includes the GJ 1 2 threadedelbow anadjustable joint is fixed so that thewasher B isfittedbetweenthecomponentsas showninthediagram A drop of paint at both edges of the L joint C will evidencethatthegoodsealoftheconnectionhas beentestedinthefactory Beforeconnectingthegassupplypipetothejoint C the installer will ensure that the paint drop is unbrokenandthe L connectorh...

Страница 6: ...1 2inchmale Rearrighthandcorner Electric 230 V 50Hz supply 3 core flexible cable with non rewireableplug ApplianceGassupply LPG30mbar ApplianceClass 3 Appliancecategory I3 Burner Nominal Power LPG Butane A Diameter Feeding Tap By Pass Pressure kW kCal h Nozzle g h mbar Auxiliary dia 42 mm 0 95 814 50 75 28 Semi rapid dia 57mm 1 60 1368 65 126 35 30 PoweredRapid dia 90mm 2 9 2475 85 228 45 1 mbar 1...

Страница 7: ...u Check that the unit is plugged in and the electrical supplyisswitchedon u Checkthemainsfusehasnotblown u Checktheburnercapandcrownhavebeen replacedcorrectly e g aftercleaning u Checkthemainjetisnotblockedandtheburner crown is clear of food particles u Checktheburnercapandcrownhavebeen replacedcorrectly e g aftercleaning If after all these checks your appliance still does not operatecorrectly con...

Страница 8: ...ctsuchasHob BriteorBarKeepersFriendisused Pan Supports To keep the pan supports in the correct position they arehookedintohingesatthebackofthehob Thepansupportscanbeliftedforeasiercleaning as shown in fig 1 Toremovethepansupportscompletely proceedas shown in fig 2 Thepansupportsaredishwasherproof Ifwashing thembyhand takecarewhendryingthemasthe enamellingprocessoccasionallyleavesroughedges Ifneces...

Страница 9: ...bottom fitting the sizeoftheburnerused seetable Ifyouuseasaucepanwhichissmallerthan therecommendedsize theflamewillspread beyondthebottomofthevessel causingthe handletooverheat As soon as a liquid starts boiling turn down the flame so that it will barely keep the liquid simmering Take care when frying food in hot oil or fat astheoverheatedsplashescouldeasily ignite If the control knobs become diff...

Страница 10: ...cription of the Hob INSTALLATION Any gas installation must be carried out by qualifiedpersonnel andinaccordancewith existingrulesandregulations Therelevantinstructionsaretobefoundinthe secondsectionofthismanual Please ensurethat oncetheapplianceis installed it is easily accessible for the engineerintheeventofabreakdown WHEN THE HOB IS FIRST INSTALLED Oncethehobhasbeeninstalled itis importanttoremo...

Страница 11: ...tallation Page 1 0 Gas Connection Page 1 0 Building In Page 1 1 Fitting the Hob to the Worktop Page 12 Electrical Connection Page 1 3 Commissioning Page 1 4 Technical Maintenance Page 1 4 Guide to Use the instructions The following symbols will be found in the text to guideyouthroughouttheInstructions SafetyInstructions Stepbystepinstructionsforan operation HintsandTips F i ...

Страница 12: ...d condition or installing a cookerhoodwithaventinghose l When using the hob for a long period time the ventilation should be improved by opening a windoworincreasingtheextractorspeed l Donotusethisapplianceifitisincontactwithwater Donotoperatetheappliancewithwethands l Ensure the control knobs are in the OFF position whennotinuse l Whenusingotherelectricalappliances ensurethe cable does not come i...

Страница 13: ...2 GAS HOB MODELS PW 64 PN 64 PX 64 PTDF 64 INSTRUCTION BOOKLET ...

Отзывы: