Zanussi NH 9015 Скачать руководство пользователя страница 9

20

GB

MAINTENANCE

Constant maintenance guarantees proper operation and long-term reliability.  Particular
attention should be paid to the metal grease filters and, for recirculation hoods only, to
the activated charcoal filters.  The appliance is equipped with a system that indicates
automatically when it is time to carry out maintenance operations

Metal  grease  filters

Cleaning

These  filters  must  be  washed  when
LED 

T2 

starts to flash, or at the most

once every 2 months, using a normal
household  detergent;  their  compact
size also enables them to be washed
in a dishwasher.

Removing  the  filters

Remove one filter at a time, supporting
it  from  below  and  pulling  back  the
stainless  steel  handle  (

fig.10

).

Replace, making sure that the handle
is still facing towards the outside.

Enabling  the  alarm  signal

The hood is already set up to trigger
an  alarm  indicating  saturation  of  the
metal grease filters, so this function does not need to be enabled.

Resetting  the  alarm  signal

To turn the alarm signal off, proceed as follows:

- Turn off the lights 

T1

 and the suction motor 

T2

;

- Press the 

T4

 button for at least 3 seconds, until the LEDs flash in confirmation.  In any

case the saturated filters alarm will only come into operation when the suction motor is
turned on.

WARNING: always comply with the maintenance and replacement times indicated,
in order to avoid a possible risk of fire when the filters are saturated with grease.

Activated  charcoal  filter

Operation

The activated charcoal filter is only fitted in recirculation type hoods.  It will retain odours
until it becomes saturated.  It cannot be washed or regenerated, and must be replaced
when the 

T5 

LED starts to flash, or at least once every 4 months of use.  Attention: in

recirculation  type  hoods  the 

T2

  LED  may  start  to  flash  as  well  as  the 

T5

  LED.    This

indicates  that  as  well  as  replacing  the  activated  charcoal  filter,  it  is  also  necessary  to
perform maintenance operations on the metal grease filters.

Fig. 10

Содержание NH 9015

Страница 1: ...kap NH 9015 MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Страница 2: ...i per l Uso 11 MANUTENZIONE 12 Filtri antigrasso metallici 12 Filtro al carbone attivo 12 Illuminazione 13 Pulizia 13 INSTALLATION 14 SAFETY WARNINGS 14 COMPONENTS 14 Installation instructions 15 Fitting the wall brackets and Splashback 15 Fixing the canopy 16 Electrical connection and working test 16 Ducting or Recirculation fitting 17 Fitting the telescopic chimney 18 OPERATION 19 Safety warning...

Страница 3: ...g appliance Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted en sure that there is an adequa...

Страница 4: ...t the other bracket 2 against the wall aligning it with the vertical line at a distance X measured as shown in fig 2 equal to the height of the upper chimney element S supplied with the hood The position X may vary according to the various sizes of upper chimney element available d Mark the centres of the keyholes in the bracket on the wall Drilling fixing holes item 1 a Mark a point on the vertic...

Страница 5: ...ktop and against the wall as illustrated in fig 2 b Mark the centres of the two holes in the top surface c Drill the wall using an 8 mm drill bit and fix the splashback using the rawl plugs and screws provided d If necessary the installer should secure the splashback to the wall by tucking the bottom edge down behind the rear of the worktop Fixing the canopy Before starting to fix the canopy it wi...

Страница 6: ...e fitted to spigot R Make sure that the height of the assembly R P corresponds to the height of the chimney outlet fig 7 If the hood is supplied with the activated charcoal filters fitted the filters should be removed see paragraph on Maintenance Recirculation fitting The filtered air is returned to the room through the two plastic side grills G on the lower chimney element I Connect the additiona...

Страница 7: ...t the lower section I as above between the upper section S and the canopy C using two of the screws provided in the bag of accessories Chimney with venting grilles Snap the venting grilles into position in the apertures located on the chimney section so that the symbol is turned upwards and the symbol faces forwards Also when the hood is used in recirculation mode ensure that the grilles are prope...

Страница 8: ...ure that the flame is kept at the correct intensity to prevent the flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking Instruction for Use Control panel The layout of the cont...

Страница 9: ...etal grease filters so this function does not need to be enabled Resetting the alarm signal To turn the alarm signal off proceed as follows Turn off the lights T1 and the suction motor T2 Press the T4 button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with...

Страница 10: ...the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease Lighting Version with halogen spotlights 90 cm model two 20W halogen spotlights To replace fig 12 Remov...

Страница 11: ... conforme à la norme européenne sur la basse tension C E E 73 23 relative à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträg...

Отзывы: