        Caution! 

Gas water heater must be installed in a location out of bathroom where well ventilated. Its 

prohibited to install natural discharge type gas water heater in a room with a poor ventilation condition. User 
should apply for local gas administrative institution approval before installation. and the installation must also 
be approved by local civil administrative department, installation should only carried out by the Service center 
which are trained well to do that.  

       

      

 

 

 

The appliance must be installed onto a vertical wall 
in a correct vertical way, and flames observation 
hole should be in human eyes level (about 140 to 
160 cm). 

 

The space of exhaust  pipes from ceiling should be 
not less than 60cm and from side walls not less than 
30cm. 

  

 

        

Caution!

  The  appliance  should  be  equipped  with 

an exhaust pipe or a chimney. Please pay attention to 
the specific regulations for installation required by the 
local country.

  

 

         

Caution! 

make sure not to mount the appliance 

on a wall contains inflammable materials, if mounted 
on an inflammable material's wall like wood put heat 
insulation material between the wall and the appliance

      

 

        Cautions! 

 

It  is  prohibited  to  put  any  inflammable  ,  exploding 
or corrosive materials close to the appliance ,never 
block the exhaust pipe with anything.

 

 

No  cables  ,electric  appliances  or  gas  pipes  can  be 
placed  above  the  appliance,  Keep  the  heater  away 
from heat sources such as gas cockers. 

 

The appliance must vertical on mounting. 

Содержание Gas Water Heater 10 liter

Страница 1: ...User manual Gas Water Heater 10 liter ...

Страница 2: ...ct the service center Never remove or damage stickers warning labels or nameplates attached to the appliance General safety Make sure that gas type used id identical to the type specified on the nameplate It is dangerous to alter the specifications or attempt to modify this product in any way unless through service center or natural gas accredited companies No touches on hot parts of the heater su...

Страница 3: ...ter away from heat sources such as gas cockers The heater must be installed onto a vertical wall in a correct vertical way Usage This appliance is designed for domestic use It must not be used for purposes other than those for which it was designed During operation do not put any inflammable or such materials close to the appliance In case of gas smell o Close the gas valve o Open all the windows ...

Страница 4: ...ontrol water flow rate on Min position it decreases the water flow to the minimum level and start up pressure to the minimum and on Max it increase water flow to the maximum and start up pressure to the maximum Gas Control knob Used to control gas flow rate on Min position it decreases the gas flow to the minimum level and on Max it increase gas flow to the maximum Digital Display Operates only wh...

Страница 5: ...n eyes level about 140 to 160 cm The space of exhaust pipes from ceiling should be not less than 60cm and from side walls not less than 30cm Caution The appliance should be equipped with an exhaust pipe or a chimney Please pay attention to the specific regulations for installation required by the local country Caution make sure not to mount the appliance on a wall contains inflammable materials if...

Страница 6: ...lation check the gas connection with soap foam for leakage use the appliance only when leakage free and passed the inspection by local gas administrative institution Batteries installation Put two D size batteries 1 5 Volt into the battery box make sure of the polarity order and close the box Exhaust pipe installation This appliance has an upper opening for exhaust connect it with an external pipe...

Страница 7: ...ition it will work all flam rows Temporary shutdown When hot water temporary not needed during use just turn off the hot water valve when hot water needed again turn on the hot water valve again Caution Be careful water temperature may be too high at the moment the water flow resumes Caution If not using for long period close water and gas supply and remove batteries Caution Be careful water tempe...

Страница 8: ...peration for only 20 minutes to protect from exhaust accumulation and in case of forgot water valve open while water source is cut and back again Care and cleaning All the repair and maintenance must be carried out by customer service authorized technicians Normally the batteries should be replaced once half a year appliance malfunctions should be repaired on its time to keep the performance of it...

Страница 9: ...nt ventilation o Remove any air intake blocking stuff from appliance sides Outlet water not hot The gas valve is not completely opened o Open the gas valve completely Flames extinguishing when adjusting water control on Max position Low inlet water pressure o Readjust water control knob towards Min position slightly until problem disappear Technical data Gas Type LPG Rated gas pressure 28mbar Rate...

Отзывы: