Electrical connection
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load;
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the forniture unit.
This appliance is supplied with connection cable (type
H05 V2V2-F (T90), section 3x 1,5 mm
2
) fitted with plug.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
a double pole switch must be installed between the
appliance and the electricity supply, with a minimum gap
of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the
current rules. The earth wire must not be interrupted by
the double switch pole.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 50 °C higher than
the room temperature.
After the connection is carried out, test the heating
elements for about 3 minutes.
Terminal block
The oven has an easily accessible terminal block, which
is meant to work with an electric single-phase rate of
230 V (Fig. 18).
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.