background image

SOMETHING NOT WORKING

Important:

If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or

installation a charge will be made, even if the appliance is under guarantee.

Before 

contacting your local Service Force Centre, check the following points:

Low room operation 

During prolonged periods of low room temperatures,ie;10°C and lower, the compressor on single compressor
fridge freezer can remain inoperative during this time .

This is due to the air temperature within the refrigerator compartment being maintained at 6°C or under thus not
calling the thermostat to energise the compressor .

Symptom

No power to the appliance

The light does not come on 

The temperature in the fridge or freezer section is
too high

The freezer door will not open

The compressor runs continously

Excessive frost and ice has built up

Noise

Water under the salad bin

Solution

Check there is power at the socket.

Check there is not a power cut by checking the
household lights.

Check the fuse has not blown.

Ensure that the bulb is correctly fitted.

Replace the bulb if it has blown.

Check the door light switch is not jammed.

Check the thermostat control knob in the fridge is
turned to the correct setting relative to ambient
conditions.

Check the ambient temperature is within the
appliance’s operating limits, please refer to the
installation section in this instruction book.
Relocate the appliance if necessary.

Has door just been opened? If so leave for a few
minutes to allow the air pressure to equalise.

Adjust the thermostat control knob to give correct
temperature control. See “Setting the temperature”.

Check that the doors are closed.

Large quantities of food have recently been placed in
the cabinet and/or door is frequently opened.

Check that air ventilation is not obstructed.

Ensure the doors are not left open.

Check that nothing is preventing the doors from
closing.

Is the door gasket intact and clean.

Has advised periodic defrosting been carried out.

Refer to normal operating sounds.

Check the drain hole is not blocked. (see
Maintenance and Cleaning).

10

Содержание ZRB 2530 S

Страница 1: ...REFRIGERATOR FREEZER ZRB 2530 W ZRB 2530 S USERMANUAL 2223 268 31...

Страница 2: ...amages to the cooling unit with consequent possible fluid leakages The appliance must not be located close to cookers radiators or boilers Avoid prolonged exposure of the appliance to direct sunlight...

Страница 3: ...aller Technical Specification 13 Installation 14 Positioning 14 Rear Spacers 14 Electrical Connection 15 Door Reversal 16 Disposal of old Appliances The symbol on the product or on its packaging indic...

Страница 4: ...tly when the room temperature drops below 16 C the switch mounted next to the thermostat control should be switched on No damage can be caused by leaving the switch in this position for any period of...

Страница 5: ...f the food is uncooked and has not been completely defrosted it can be cooked and then refrozen Meat fish and fruit should be thawed in the refrigerator compartment and small pieces of meat can even b...

Страница 6: ...helves The walls of the refrigerator have runners so that shelves can be positioned as desired The door shelves can be easily removed for cleaning Gently ease the shelves in the direction of the arrow...

Страница 7: ...y in between The fresh foods to be frozen must be fresh and of the best quality The size of each pack should be small enough to ensure that it is used in one go Small packs freeze more quickly and uni...

Страница 8: ...condenser black grill and the compressor at the back of the appliance with a brush or vacuum cleaner see figure PR259 Before any maintenance or cleaning work is carried out DISCONNECT the appliance f...

Страница 9: ...ect the appliance to the mains or reset the thermostat control knob to a functioning position After letting the appliance run for at least half an hour replace the previously removed food into the com...

Страница 10: ...re is not a power cut by checking the household lights Check the fuse has not blown Ensure that the bulb is correctly fitted Replace the bulb if it has blown Check the door light switch is not jammed...

Страница 11: ...ceforce co uk Before calling out an engineer please ensure you have read the details under the heading Something Not Working When you contact the Service Force Centre you will need to give the followi...

Страница 12: ...alls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial envi...

Страница 13: ...z TOTAL POWER ABSORBED 110 W AVERAGE DAILY UNITS ELECTRICITY 0 838 kWh GROSS CAPACITY Fridge 149 l Freezer 104 l NET CAPACITY Fridge 145 l Freezer 85 l This figure is based on standard test results in...

Страница 14: ...be a gap of 25 mm either side of the appliance Do not obstruct the space underneath The back of the cabinet may be placed close to the wall but must not touch it DO NOT install in places with restric...

Страница 15: ...e plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black...

Страница 16: ...vided on the opposite side after having removed the small plugs I which should then be fitted on the opposite side 9 Refit the fridge door and replace the middle hinge to the left hand side 10 Replace...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...Electrolux plc 2007 www electrolux com www zanussi electrolux co uk...

Отзывы: