Commissioning

When the hob has been fully installed it will be necessary
to check the minimum flame setting. To do this, follow
the procedure below.
-

Turn the gas tap to the MAX position and ignite.

-

Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times. If
the flame is unstable or is extinguished follow the
procedure below.

)

 

Procedure:

-

Re-ignite the burner and set to MIN.

-

Remove the control knob and use a thin bladed
screwdriver to turn the adjustment screw until the flame
is steady and does not extinguish, when the knob is
turned from MIN to MAX.

-

The adjustment screw may be located at the centre
of the gas tap control shaft or on the gas tap body,
left of the control shaft or below (see diagram).

-

Repeat the adjustment procedure for all burners.

Adjustment

screw

)

 

Pressure Testing

-

Remove left hand pan support and front left burner
cap and crown.

-

Fit manometer tube over the injector.

-

Turn on the burner gas supply and ignite another
burner.

-

The pressure reading should be nominally 20mbar
and must be between 17 mbar and 25mbar.

-

Turn off the burner supplies.

Electrical connections

Neutral

Earth (yellow/green)

The appliance is designed to be connected to 220 V
monophase electricity supply.
The connection must be carried out in compliance with
the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation

can support the load (see the rating label);

2) check that the power supply is properly earthed in

compliance with the current rules;

3) check the socket or the double pole switch used for

the electrical connection can be easily reached with
the appliance built in the forniture unit.

Connect the plug, able to support the load marked on the
identification plate, to the cable. The plug has to be fitted
in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The earth cable (yellow/green) must not be interrupted by
the interrupter.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature of 90 °C.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.

Содержание ZGF 98

Страница 1: ......

Страница 2: ...can cause an accident by tipping or spillage z Never leave the hob unattended when cooking with oil and fats z Never use plastic or aluminium foil dishes on the hob z Perishable food plastic items and areosols may be affected by heat and should not be stored above or below the hob unit Service z This hob should only be repaired or serviced by an authorised Service Engineer and only genuine approve...

Страница 3: ...ription of the Hob Important Safety Information 12 Description of the Hob 13 Operation 14 Maintenance and Cleaning 15 Something Not Working 16 Service and original spare parts 16 Instructions for the Installer 17 Important safety requirements 18 Installation 19 Conversion from LPG to Natural Gas 19 Commissioning 20 Electrical connections 20 Building In 21 1 AuxiliaryBurner 2 Semi rapidBurners 3 Ul...

Страница 4: ...uld only use pots and pans with a flat bottom fitting the size of the burner used see table Burner minimum maximum diameter diameter Ultra rapid triple crown 180 mm 260 mm Large rapid 180 mm 260 mm Medium semi rapid 120 mm 220 mm Small auxiliary 80 mm 160 mm If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to ...

Страница 5: ...r A well moistenedsoapimpregnatedsteelwoolpadcanbeused with caution if the marks are particularly difficult to remove After cleaning be sure to wipe dry with a soft cloth Ignition electrode The electric ignition is obtained through a ceramic and metal electrode Fig 1 letter C Keep these components very clean to avoid lighting difficulties and check that the burner crown holes are not obstructed Ca...

Страница 6: ...it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Service and original spare parts This machine before leaving the factory has been tested and studied by many experts and specialists in order to give...

Страница 7: ...0 Ultra rapid 56 Aerationadjustmentnone Instructions for the Installer Engineers technical data APPLIANCE CLASS 3 APPLIANCE GAS SUPPLY gas G28 30 37mbar BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 3 0 0 65 2 0 0 45 1 0 0 33 4 0 1 2 NOMINALFLOW RATE m3 h 0 286 0 062 0 190 0 043 0 095 0 031 0 381 0 114 NOZZLE REFERENCE 119 Adj...

Страница 8: ...ceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathr...

Страница 9: ... to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 FO 0264 Conversion from LPG to Natural Gas IMPORTANT The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with LPG gas but can be converted for use with Natural gas providing the correct injectors are f...

Страница 10: ... supplies Electrical connections Neutral Earth yellow green The appliance is designed to be connected to 220 V monophase electricity supply The connection must be carried out in compliance with the laws and regulations in force Before the appliance is connected 1 checkthatthemainfuseandthedomesticinstallation can support the load see the rating label 2 check that the power supply is properly earth...

Страница 11: ... removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections 1 FO 2563 2 Fitting the Hob into the worktop Carry out the building in of the hob as follows place the seals supplied with the hob on the side edges of the cut out and at 8 mm from the front and rear edges as shown in the diagram taking care that the seals meet without ...

Страница 12: ......

Страница 13: ......

Страница 14: ...Grafiche MDM Forlì 35692 6601 AM 05 06 ...

Отзывы: