NOFROST REFRIGERATORS WITH ELECTRONIC TIMER
15/29
6.3 FREEZER COMPARTMENT:
- fan
D
;
- couple of thermal overload cut-outs
E
(for technical data see
Tab. A
)
- evaporator battery
F
- defrosting heater
G
(for technical data see
Tab. B
)
Tab. A
Tab. B
pnc Refrigerating
gas
Voltage Resistance Power
Notes
925886xxx R134a 240
V
242
Ω
238
W
-
925886xxx R600a 240
V 213
Ω
(see notes)
271 W
Total value of the 2 heating
elements
925887xxx R134a 240
V
220
Ω
262
W
-
925887xxx R600a 240
V 207
Ω
(see notes)
278 W
Total value of the 2 heating
elements
925888xxx R134a 240
V
220
Ω
262
W
-
925888xxx R600a 240
V 207
Ω
(see notes)
278 W
Total value of the 2 heating
elements
CUT-IN TEMPERATURE
TYPE OF THERMAL
OVERLOAD CUT-OUT
OPENING CLOSURE
DEFROSTING
+ 8 °C
- 1 °C
SAFETY
+ 40 °C
+ 30 °C