OPERATION
25
Synthesis
06/40V GAS
This variation in the temperature value is effected to correct the only value taken in the
coldest part of the oven and to simulate a value near to the real one previously elaborated by
making the average between the hottest and coldest points. This allows the oven to be used
even when a probe breaks.
5.6.3
“OVER”
If the temperature measured by the probe 1 exceeds 350°C and, at the same time, probe 2
exceeds 450°C, the temperature value on the display is replaced by the flashing word “OVER”
and the alarm sounds intermittently.
You can switch off the alarm by pressing the key
.
necessary to call in specialists to restore functionality
5.6.4
“BELT”
When the conveyor motor is broken or sends wrong signals to the circuit board, the word
“BELT” (“RETE”) flashes on the display and the alarm sounds intermittently.
This means that the cooking time does not correspond to the set value and that specialized
personnel are required to reset the functions of the oven.
5.6.5
“FAN”
If the pressure regulator fails for 5 consecutive seconds when the fan is on, the temperature
value on the display is replaced by the flashing word “FAN”, the buzzer sounds intermittently
and the oven heating (if on) switches off. The alarm switches off automatically when the
pressure regulator contact is re-established or the oven is switched off (after the switching off
phase). The correct functioning of the pressure regulator should then be checked.
While the alarm sounds, fan and conveyor (if on) remain activated.
The buzzer can be silenced by pressing the key
.
5.6.6
“PRESS”
If there is no pressure regulator (before switching on the fan), the word OFF is replaced by
the flashing word “PRESS”, the alarm sounds intermittently and the switching on procedure
terminates.
To reset the functioning of the oven, check that the pressure regulator is working properly. To
do this, check that the pipes are connected without any constriction. If necessary, adjust the
calibration with the screw located at the centre of the pressure regulator. The buzzer can be
silenced by pressing the key
.
Содержание SYNTHESIS 06/40V GAS
Страница 35: ...MAINTENANCE 35 Synthesis 06 40V GAS Fig 10 1 Wiring diagram for synthesis 06 40V gas 230 Vac 1 N 50 60Hz...
Страница 38: ...MAINTENANCE 38 Synthesis 06 40V GAS FIG 10 2 Exploded view Synthesis 06 40V gas components of carpentry...
Страница 39: ...MAINTENANCE 39 Synthesis 06 40V GAS FIG 10 3 Exploded view Conveyor Synthesis 06 40V gas...
Страница 44: ...DECLARATION OF CONFORMITY 44 Synthesis 06 40V GAS 10 DECLARATION OF CONFORMITY...