4. INSTALLATION
CITIZEN EP70
13
the feed characteristics required by the equipment itself (see 3 and plate
on equipment).
The feed cable must end in a plug which connects to an electrical feed
panel with a corresponding socket and a different magneto thermal switch.
The plug-socket connection must be such that the earth lead is
connected first and disconnected last and must be of the correct size for
the nominal current (see 3). Suitable plugs and the industrial type CEE 17
of any which satisfy the European Norm EN 60309.
The thermal safety device must be set for the total nominal current, the
magnetic safety device must be set for the instantaneous maximum current
(in the case of ovens it is a little above the nominal figure, in the case of
machines it is the pick up current for the most powerful motor) , while the
differential device must be set to the 30 mA current (see 3.) .
The manufacturer shall not be liable for any damage which results from
failure to observe the above mentioned norms.
See figure 4.4, figure 4.5 for the exact position of the feed cable output.
4.5
Emissions from cooking appliance
ATTENTION!
Proceed with the installation of the oven
according to the norms defined by current legislation in the country
concerning the installation of this typology of oven so as to guarantee
the sustainability of a healthy working environment. For more
information it is recommended that specific norms be consulted.
For the oven to work well, it is necessary to check that the
exhaust system is drawing properly to expel vapors and cooking
smells.
The Manufacturer cannot answer for damage caused by ignoring
these abovementioned norms as well as the information in this
manual.
For the position of the vapor exhaust connections see Fig. 4.4 for the
unit without top, Fig. 4.5 for the unit with top.
Содержание CITIZEN EP 70/4+4
Страница 2: ......
Страница 25: ...8 MAINTENANCE CITIZEN EP70 25 Fig 8 1 Electrical diagram Citizen EP70 single chamber at 400 Vac 3 N version...
Страница 26: ...8 MAINTENANCE 26 CITIZEN EP70 Fig 8 2 Electrical diagram Citizen EP70 single chamber at 230 Vac 3 version...
Страница 27: ...8 MAINTENANCE CITIZEN EP70 27 Fig 8 3 Electrical diagram Citizen EP70 single chamber at 230 Vac 1 N version...
Страница 28: ...8 MAINTENANCE 28 CITIZEN EP70 Fig 8 4 Electrical diagram Citizen EP70 double chamber at 400 Vac 3 N version...
Страница 31: ...8 MAINTENANCE CITIZEN EP70 31 Figure 8 7 Exploded view...
Страница 33: ...8 MAINTENANCE CITIZEN EP70 33 Figure 8 8 Exploded view of electrical parts...
Страница 34: ...8 MAINTENANCE 34 CITIZEN EP70 Figure 8 9 Exploded view of electrical parts...