background image

38

Installation

ª

During normal operation, the condenser and 
compressor at the back of the appliance heat up 
considerably. For safety reasons, minimum 
ventilation must be as shown in the relevant 
Figure.
Attention: keep ventilation openings clear of 
obstruction.

ª

If the appliance is transported horizontally, it is 
possible that the oil contained in the compressor 
flows in the refrigerant circuit. It is advisable to 
wait at least two hours before connecting the 
appliance to allow the oil to flow back in the 
compressor.

ª

There are working parts in this product which heat 
up. Always ensure that there is adequate 
ventilation as a failure to do this will result in 
component failure and possible food loss. See 
installation instructions.

ª

Parts which heat up should not be exposed. 
Wherever possible the back of the product should 
be against a wall.

ª

If the appliance has been transported horizontally, 
it is possible that the oil contained in the 
compressor flows in the refrigerant circuit. It is 
advisable to wait at least two hours before 
connecting the appliance to allow the oil to flow 
back in the compressor.

Environment Protection

ª

This appliance does not contain gasses which 
could damage the ozone layer, in either its 
refrigerant circuit or insulation materials. The 
appliance shall not be discarded together with 
the urban refuse and rubbish. Avoid damaging 
the cooling unit, especially at the rear near the 
heat exchanger. Information on your local 
disposal sites may be obtained from your 
municipal authorities.
The materials used on this appliance marked 
with the symbol 

 are recyclable.

Содержание ZKK9010

Страница 1: ...K hlschr nke ZANKER ZKK 9010 R frig rateurs ZKK 9012 Koelkasten Refrigerators Gebrauchsanweisung Mode d emploi Gebruiksaanwijzing Instruction booklet 2222 146 91...

Страница 2: ...Service Centre and always insist on genuine spare parts This appliance contains hydrocarbons in its cooling unit maintenance and recharging must therefore only be carried out by authorized technicians...

Страница 3: ...od loss See installation instructions Parts which heat up should not be exposed Wherever possible the back of the product should be against a wall If the appliance has been transported horizontally it...

Страница 4: ...1 Electrical connection 43 Technical specification 43 Use 44 Operation 44 Temperature regulation 44 Fresh food refrigeration 44 Movable shelves 45 Positioning the door shelves 45 Defrosting 45 Mainten...

Страница 5: ...rpose the supply cable plug incorporates a special earth contact If the sockets of your domestic wiring system are not earthed have the appliance connected to a separate earth wire by a qualified elec...

Страница 6: ...relevant pins at the top and at the bottom For safety reasons minimum ventilation must be as shown in Fig 1 Attention keep ventilation openings clear of obstruction Push appliance into the housing unt...

Страница 7: ...unit as shown in Fig 6 and mark the position of the external holes After preparing the holes screw the runners to the kitchen unit door using 3 5x16 mm screws Open both the appliance door and that of...

Страница 8: ...check that the doors of the appliance and the kitchen unit open properly Electrical connection Before plugging in ensure that the voltage and frequency shown on the serial number plate correspond to y...

Страница 9: ...causing frost to form on the rear wall In this case the dial must be set to a higher temperature to allow automatic defrosting and therefore reduced energy consumption Fresh food refrigeration To obt...

Страница 10: ...es off then reposition as required Defrosting Frost is automatically eliminated from the evaporator of the refrigerator compartment every time the motor compressor stops during normal use The defrost...

Страница 11: ...y pressing it as shown in the figure If the door is open and the light does not come on check that the bulb is properly screwed in if it still does not work replace the bulb with one of the same power...

Отзывы: