8
Installation
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
!
Material losses
Observe the max. permissible inlet temperature. Hig-
her temperatures may damage the appliance. You
can limit the inlet temperature by means of a central
thermostatic valve.
!
Material losses
Only operate the appliance with non-pressurised
taps.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regula-
tions and instructions.
The specific electrical resistance of the water must not fall
below that stated on the type plate. In a linked water net-
work, factor in the lowest electrical resistance of the water
(see chapter „Specification / Data table“). Your water sup-
ply utility will advise you of the specific electrical water
resistance or conductivity.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
◦ Sieve inside the cold water inlet
◦ Special aerator „SR“
◦ Company logo for oversink installation
8.2 Accessories
Special aerator „SR“*
◦ SR 3: Part number 289591
for MDO 35 and MDO 44
◦ SR 5: Part number 270582
for MDO 57
* For use in thread M22/M24.
Non-pressurised taps
◦ Ü 136 Twin lever basin tap
◦ AHo 40 MTH
Oversink installation