background image

12

ADVANCED SETTINGS

The Advanced Settings can be accessed by pressing and holding 

 while 

powering on the display. The Advances Settings include:

•  Door unlock time 

1-10; 20, 30, 40, 50, 60, 70, 80, 90, 99 s

•  Gate status 

Normally open electric catch contact (NO) 
Normally closed electric catch contact (NC)

•  Gate unlock time 

0.2, 0.5, 1-5 s

•  System type 

Single-family 
Multi-family

WARRANTY

24-month commercial warranty by the manufacturer

Reseller’s stamp and signature  

with date of sale

1. ZAMEL Sp. z o.o. Gives a 24-month warranty for 

 

the goods it sells.

2. The warranty given by ZAMEL Sp. z o.o. does not cover: 

a) mechanical damage caused by transport, 

loading/unloading 

or 

other 

circumstances; 

b) damage caused by improper installation or operation 

of  the  goods  manufactured  by  ZAMEL  Sp.  z  o.o.; 

c) damage caused by any modifications made by the BUYER 

or any third party to the sold goods or to the equipment 

required  for  the  proper  functioning  of  the  sold  goods; 

d) damage caused by any force majeure 

event or another fortuitous event beyond 

any  reasonable  control  of  ZAMEL  Sp.  z  o.o.; 

e) the power supply (batteries) included (if any) with the 

device as sold.

3. The BUYER shall make all warranty claims in writing at the point of sale or to ZAMEL Sp. z o.o.

4. ZAMEL Sp. z o.o. will examine each warranty claim as regulated by the applicable provisions of the Polish law.

5. The form of warranty claim resolution, i.e. replacement, repair or refund of the price of purchase, shall  

be decided by ZAMEL Sp. z o.o.

6. This warranty does not exclude, limit or suspend any rights of the BUYER arising from the statutory  

or regulatory laws concerning implied warranty for defects of sold goods.

Содержание VP-819B

Страница 1: ...esults of damage and or accidents caused by non intended use of the product Before attempting to install this product please read and understand the entire Operating Manual to comply with the intended...

Страница 2: ...nds Electrocution hazard Do not attempt to disassemble repair or alter this product on your own Risk of electrocution damage to the product and or fire Do not install a current breaker on the mains co...

Страница 3: ...CTION DIAGRAM AD Audio VD Video PWR Power GND Ground DATA Data communication CCTV CCTV feed in KEY1 KEY2 Control voltage J4 J4 J4 J4 ROOM 1 ROOM 2 ROOM 3 ROOM 4 ELECTRIC CATCH 2 ELECTRIC CATCH 1 DISPL...

Страница 4: ...power GND and KEY1 contacts c External power supply port J4 optional d Wiring connection diagram for the NC06 gate control module Connector P3 GND and DATA to NC06 COM NO NC to gate control AD Audio V...

Страница 5: ...meras to which they are connected All displays can output the video feed of a CCTV camera connected to the entrance panel port AD Audio VD Video PWR Power GND Ground DATA Data communication CCTV CCTV...

Страница 6: ...4 wideo monitory 2 kamery CCTV do ka dego monitora DRZWI 1 KAMERA1 KAMERA2 KAMERA1 KAMERA1 KAMERA1 KAMERA2 KAMERA2 KAMERA2 DRZWI 2 DRZWI 1 KAMERA1 KAMERA2 KAMERA1 KAMERA1 KAMERA1 KAMERA2 KAMERA2 KAME...

Страница 7: ...onnections are correct 2 Choose a suitable location in which to install the display unit An installation height between 1 5 and 1 6 m above the ground is recommended 3 Verify that the power supply vol...

Страница 8: ...entrance panel is 30 m away from the video entry phone display use YTDYw 4 x 0 5 mm2 wiring ENTRANCE PANEL ELECTRIC CATCH 1 2 3 4 1 2 3 4 RED BLUE YELLOW WHITE RED BLUE YELLOW WHITE GREEN BROWN If th...

Страница 9: ...h and hold again to unmute your microphone which the display will confirm with SPEAK Operating a gate requires the NC06 gate control module in the system VIDEO FEED MONITORING With the display on stan...

Страница 10: ...th or DO NOT DISTURB MODE You can enable or disable the DO NOT DISTURB mode in the display System Settings menu Touch and hold to enable or disable this mode DISPLAY MICROPHONE MONITORING With the dis...

Страница 11: ...icrophones can be enabled in the System Settings 6 MONITOR UNLOCK Touch to unlock the electric catch linked to the entrance panel Touch to open the gate linked to the entrance panel 7 DEVICE ADDRESS R...

Страница 12: ...peration of the goods manufactured by ZAMEL Sp z o o c damagecausedbyanymodificationsmadebytheBUYER or any third party to the sold goods or to the equipment required for the proper functioning of the...

Отзывы: