background image

Download SUPLA application to your smartphone. 

If you already have a SUPLA account and are logged in to the application, go to the next point.

If you do not have an account, then in the application click: Create an account. Enter your e-mail 

address and password in the form. Check your e-mail . Confirm the registration by clicking  

the activation link in the e-mail sent. Then log in to the application with your e-mail address.

Connect the device to the power supply according to the wiring diagram provided on the device.

After logging in correctly, select „Add device” from the application menu.  

The Add Device Wizard is launched. Follow the on-screen instructions until the configuration  

is successful. After proper configuration, the device will connect to the Wi-Fi router.  

This will be indicated by a continuous LED light. 

You can also connect to „ZAMEL-SLW-02...” Wi-Fi network. In the web browser bar,  

enter the address: 192.168.4.1, then complete your Wi-Fi data and the e-mail address  

you used when registering your account, and press the SAVE button. Correct saving of access  

settings will be confirmed by the message „Data saved”. After this operation, press  

the CONFIG button to store the settings.

Control LED lights remotely using the SUPLA app on your smartphone!

Add a device 

Create account / log in

@

Connect to power supply

Install the application 

DETAILED INSTRUCTION MANUAL AVAILABLE AT:

https://zamel.com/en/supla/slw-02-manual.pdf

control lights

SLW-02 – LED lights control module

TECHNICAL DATA

Rated supply voltage: 

12

÷

24 V DC

Rated power consumption: 

0.4 W

Transmission: 

Wi-Fi 2.4 GHz b/g/n

Operating range: 

Wi-Fi range

Number of inputs: 

1

Number of output channels: 

3 x PWM transistor

Maximum output current-carrying capacity:  2 A / per channel

Number of connection terminals: 

6 (conductor cross-section up to 2.5 mm

2

)

Enclosure mounting: 

installation box Ø 60 mm

Operating temperature range: 

-10 to +55°C

Enclosure protection rating: 

IP20

Dimensions: 

47.5 × 47.5 × 20 mm

Weight: 

0.04 kg

Reference standards: 

EN 60669-1, EN 60669-2-1, ETSI EN 300 328, 

 

ETSI EN 301 489-1, EN 301 489-17

INSTALLATION CONSIDERATIONS:

1.  Do not install receivers close to one another (if possible, maintain spacing of at least 15 cm  

between individual receivers). In particular, avoid installing receivers on top of one another.  

It may result in Wi-Fi connectivity problems.

2.  Observe the maximum output current-carrying capacity value: 

• 12 V LED light bars: 5 m – 70 W 

• 24 V LED light bars: 10 m – 140 W

3.  During installation, ensure the module is not subjected to direct water impact or operation  

in high moisture content environments. The range of temperatures in the installation location  

should be from -10 to +55°C.

4.  SLW-02 modules are to be installed indoors. When installed outdoors, it must be secured  

in an additional airtight installation box.

5.  Installation connectors for wired control can be connected to SLW-02 receiver input IN1.  

The input operates with monostable or bistable connectors. The default input IN1 operates  

in a monostable mode (bell).

6.  After receiver installation, check its operation, ensuring that the LED is ON.

INSTALLATION

•  SLW-02 modules are to be mounted in installation boxes. The enclosure dimensions facilitate 

installation in flush-mounted (minimum Ø 60) and surface-mounted boxes. For flush mounting, 

“pocket boxes” are recommended.

•  Connect the device to a stabilised power supply, according to applicable standards. The device 

must be installed, connected and adjusted by qualified electricians familiar with its operation 

manual and functions. Due to safety reasons, do not install the device with its enclosure removed 

or damaged, as it poses an electric shock risk.