power socket and lights control module ROW-02
TECHNICAL DATA
Rated supply voltage:
230 V AC
Rated mains frequency:
50 / 60 Hz
Rated power consumption:
1.2 W
Transmission:
Wi-Fi 2.4 GHz b/g/n
Operating range:
Wi-Fi range
Number of inputs:
2
Compatible connectors:
monostable (bell buttons), bistable (standard light
switches without backlight function)
Number of output channels:
2
Relay contact parameters:
2 x NO 5 A / 250 V AC
Maximum output current-carrying capacity:
2 x 5 A / 250 V AC
Number of connection terminals:
6 (conductor cross-section up to 2.5 mm
2
)
Enclosure mounting:
installation box Ø 60 mm
Operating temperature range:
-10 to +55°C
Enclosure protection rating:
IP20
Dimensions:
47.5 x 47.5 x 23 mm
Weight:
0.046
g
Reference standards:
EN 60669-1, EN 60669-2-1, ETSI EN 300 328,
ETSI EN 301 489-1, EN 301 489-17
INSTALLATION CONSIDERATIONS:
1. Do not install receivers close to one another (if possible, maintain spacing of at least 15 cm between
individual receivers). In particular, avoid installing receivers on top of one another. It may result
in Wi-Fi connectivity problems.
2. Observe the maximum output current-carrying capacity value:
• incandescent and halogen light bulbs: 750 W / per channel
• compact fluorescent lamps (CFL): 250 W / per channel
• LED lamps: 60 W / per channel
3. During installation, ensure the module is not subjected to direct water impact or operation in high
moisture content environments. The range of temperatures in the installation location should be
from -10 to +55°C.
4. ROW-02 modules are to be installed indoors. When installed outdoors, it must be secured
in an additional airtight installation box.
5. Installation connectors for wired control can be connected to inputs IN1 and IN2 of the ROW-02
receiver. The inputs operate with monostable or bistable connectors. The default IN1 input operates
with a monostable (bell) mode, and IN2 operates in a bistable mode (standard light switches without
a backlight function). ROW-02 modules are to be mounted in installation boxes. The enclosure
dimensions facilitate installation in flush-mounted (minimum Ø 60) and surface-mounted boxes.
For flush mounting, “pocket boxes” are recommended.
6. After receiver installation, check its operation, ensuring that the LED is ON.
INSTALLATION
• ROW-02 modules are to be mounted in installation boxes. The enclosure dimensions facilitate
installation in flush-mounted (minimum Ø 60) and surface-mounted boxes. For flush mounting,
“pocket boxes” are recommended.
• Connect the device to single-phase mains, according to applicable standards. The device must
be installed, connected and adjusted by qualified electricians familiar with its operation manual
and functions. Due to safety reasons, do not install the device with its enclosure removed
or damaged, as it poses an electric shock risk.
Download SUPLA application to your smartphone.
If you already have a SUPLA account and are logged in to the application, go to the next point.
If you do not have an account, then in the application click: Create an account. Enter your e-mail
address and password in the form. Check your e-mail . Confirm the registration by clicking
the activation link in the e-mail sent. Then log in to the application with your e-mail address.
Connect the device to the power supply according to the wiring diagram provided on the device.
After logging in correctly, select „Add device” from the application menu.
The Add Device Wizard is launched. Follow the on-screen instructions until the configuration
is successful. After proper configuration, the device will connect to the Wi-Fi router.
This will be indicated by a continuous LED light.
You can also connect to „ZAMEL-ROW-02...” Wi-Fi network. In the web browser bar,
enter the address: 192.168.4.1, then complete your Wi-Fi data and the e-mail address
you used when registering your account, and press the SAVE button. Correct saving of access
settings will be confirmed by the message „Data saved”. After this operation, press
the CONFIG button to store the settings.
Control lights and power sockets remotely using the SUPLA app on your smartphone!
Add a device
Create account / log in
@
Connect to power supply
Install the application
DETAILED INSTRUCTION MANUAL AVAILABLE AT:
https://zamel.com/en/supla/row-02-manual.pdf
control lights
plik: ROW-02_interowy | __KR102113 | modyfikacja: 13.05.2020