PROGRAM SETTING

PROGRAM ASSIGNING

 

- program no. assigning to a week’s day; enter by pressing OK;

 With 

 cursors select a week’s day for edition; select by pressing OK;

 With   select the program no. to assign to the given day; after acknowledgement by pressing 

OK the week’s day selection   window will be open.

 

 - iewing and setting programs, enter by pressing OK;

 With 

 cursors select a program  for edition, acknowledge by pressing OK;

 After the program no. selection it is possible to view its contents by means of cursors 

 the program data will be displayed with 15 min. steps. In order to edit 

program press OK;

 With 

 cursors select an op mode (temperature) for 0:00 hour, con

fi

 rm with OK;

 After the mode selection with 

 cursors  select last hour for the preset temperature maintaining; acknowledge by pressing OK; if the given temperature is to be 

the same for the whole program duration, press the key   in order to save the given mode to the remaining program memory;

 After the hour acknowledgement by pressing OK, with 

 select another op mode for the previously set time (select an hour as described  in  entry  ); con

fi

 rm 

with OK;

 With 

 select last hour for the preset temperature maintaining –  after pressing the key   the settings will be saved and the program viewing mode will start.

Prog 0

Non-editable program: 24 hrs

non-freeze temperature 

Prog 1

00:00 - 06:00 - econo temperature 

06:00 - 23:00 - comfort temperature   

23:00 - 00:00 - econo temperature 

Prog 2

00:00 - 06:00 - econo temperature 

06:00 - 08:00 - comfort temperature 

08:00 - 16:00 - output temperature 

16:00 - 23:00 - comfort temperature 

23:00 - 00:00 - econo temperature 

Prog 3

00:00 - 06:00 - econo temperature 

06:00 - 08:00 - comfort temperature 

08:00 - 10:00 - output temperature 

10:00 - 12:00 - comfort temperature 

12:00 - 16:00 - output temperature 

16:00 - 23:00 - comfort temperature 

23:00 - 00:00 - econo temperature 

Prog 4

00:00 - 06:00 - comfort temperature 

06:00 - 13:00 - econo temperature 

13:00 - 15:00 - comfort temperature 

15:00 - 22:00 - econo temperature 

22:00 - 00:00 - comfort temperature 

Prog 5

24 hrs econo temperature 

Prog 6-9

Empty – for the user’s edition - set by default: 

comfort temperature 

t[h]

t[h]

t[h]

t[h]

t[h]

t[h]

t[h]

temperature

TEMPERATURE SETTING

EXTERNAL INPUT SETTING

SENSOR ADAPTATION SETTING

 

 - temperature setting; press OK in order to view and edit; with 

 cursors select the 

temperature to set:

Window  : Non-freeze temperature  - the user is not allowed to change it;
Window  : Comfort temperature (day) – in order to change the set value press OK; with cur-
sors 

 set temperature demanded  ; con

fi

 rm with OK.

Window  : Econo temperature (night)  -  in order to change the set value press OK; with cur-
sors 

 set temperature demanded  ; con

fi

 rm with OK.

Window  : Output  temperature  - in order to change the set value press OK; with cursors 

 

set temperature demanded  ; con

fi

 rm with OK.

It is possible to exit every sub- menu window in any moment without saving settings by pressing the button   or  .

It is possible to exit every sub- menu window in any moment without saving settings by pressing the button   or  .

 

 -  setting the op mode for  the unit after  IN external input triggering; enter edition after 

pressing OK; with cursors 

 select an appropriate external input mode, where:

 

 - external input function OFF;

   - manual mode –  temperature setting: non-freeze;
 

 - manual mode – temperature setting: comfort;

 

- manual mode – temperature setting: econo;

   - automatic op mode – temperature setting according to the program selected;
   - manual op mode – temperature setting: output;

Con

fi

 rm the selected mode by pressing OK.

Sensor adaptation setting – If there are any differences between real and measured tempera-
ture, it is possible to correct the error by means of the sensor correction:

 Enter the adaptation temperature setting mode by pressing OK;
 With 

 cursors select temperature correction within the range  -4,5°C  ÷ +4,5°C; con

fi

 rm 

selection by pressing OK.

It is possible to exit every sub- menu window in any moment without saving settings 
by pressing the button   or  .

MAIN RESET

 In order to cancel the clock system (time, date, activity of given functions etc.) you should 

hold buttons (  and  ) simultaneously in the main menu for 

3 sec

;

 All the display 

fi

 elds will light up;

 After a while,  the clock will automatically set date and time.

Attention: In order to restore factory settings, you should additionally hold button OK

CONNECTIONS

ASSEMBLY

APPLICATION

CASING DIMENSIONS

PRODUCT FAMILY

The RTM-20 regulator is a member of

the RTM product family.

1.  Disconnect the electric network by me-

ans of an appropriate cut-off, current- li-
miting circuit-breaker or separator.

2.  Check if there is no any voltage be-

tween power leads by means of an 
appropriate gauge.

3.  Mount the RTM-20 regulator on TH 35 

rail.

4.  Connect the system leads to the termi-

nals according to the electric diagram.

5.  Connect power supply circuit.

INNER DIAGRAM

L
N

Device version:
01 - basic
20 – with the LCD
display

Device type

RTM - xx

TIME CHARTS

230 V AC mains

RTM-20
mounting
place

fl

 oor 

pouring 3-5 cm

pouring 1-2 cm

foamed
polystyrene

foundation

heating
cable

heating

NTC probe
in a protection pipe

The RTM-20 tempera-
ture regulator may be 
used for the 

fl

 oor  heat-

ing systems control 
combined with Zamel 
NTC-03 temperature 
sensor.

czujnik NTC

230V

heating

junction box

μ

C

KLAW.

LCD

ZAS.

NTC

NTC

A1

A2

IN

14

12

11

A/C

RTC

IN

T=1

o

C

L/N

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modi

fi

 cations made by the PURCHASER or any third parties to the product or any other devices 

needed for the product functioning, 

d)  damage caused by Act of God or any other incidents independent of the manufacturer.

3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement  or money return. 
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s  statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or 

otherwise are not affected by this warranty.

Отзывы: