PROGRAM SETTING
PROGRAM ASSIGNING
- program no. assigning to a week’s day; enter by pressing OK;
With
cursors select a week’s day for edition; select by pressing OK;
With select the program no. to assign to the given day; after acknowledgement by pressing
OK the week’s day selection window will be open.
- iewing and setting programs, enter by pressing OK;
With
cursors select a program for edition, acknowledge by pressing OK;
After the program no. selection it is possible to view its contents by means of cursors
the program data will be displayed with 15 min. steps. In order to edit
program press OK;
With
cursors select an op mode (temperature) for 0:00 hour, con
fi
rm with OK;
After the mode selection with
cursors select last hour for the preset temperature maintaining; acknowledge by pressing OK; if the given temperature is to be
the same for the whole program duration, press the key in order to save the given mode to the remaining program memory;
After the hour acknowledgement by pressing OK, with
select another op mode for the previously set time (select an hour as described in entry ); con
fi
rm
with OK;
With
select last hour for the preset temperature maintaining – after pressing the key the settings will be saved and the program viewing mode will start.
Prog 0
Non-editable program: 24 hrs
non-freeze temperature
Prog 1
00:00 - 06:00 - econo temperature
06:00 - 23:00 - comfort temperature
23:00 - 00:00 - econo temperature
Prog 2
00:00 - 06:00 - econo temperature
06:00 - 08:00 - comfort temperature
08:00 - 16:00 - output temperature
16:00 - 23:00 - comfort temperature
23:00 - 00:00 - econo temperature
Prog 3
00:00 - 06:00 - econo temperature
06:00 - 08:00 - comfort temperature
08:00 - 10:00 - output temperature
10:00 - 12:00 - comfort temperature
12:00 - 16:00 - output temperature
16:00 - 23:00 - comfort temperature
23:00 - 00:00 - econo temperature
Prog 4
00:00 - 06:00 - comfort temperature
06:00 - 13:00 - econo temperature
13:00 - 15:00 - comfort temperature
15:00 - 22:00 - econo temperature
22:00 - 00:00 - comfort temperature
Prog 5
24 hrs econo temperature
Prog 6-9
Empty – for the user’s edition - set by default:
comfort temperature
t[h]
t[h]
t[h]
t[h]
t[h]
t[h]
t[h]
temperature
TEMPERATURE SETTING
EXTERNAL INPUT SETTING
SENSOR ADAPTATION SETTING
- temperature setting; press OK in order to view and edit; with
cursors select the
temperature to set:
Window : Non-freeze temperature - the user is not allowed to change it;
Window : Comfort temperature (day) – in order to change the set value press OK; with cur-
sors
set temperature demanded ; con
fi
rm with OK.
Window : Econo temperature (night) - in order to change the set value press OK; with cur-
sors
set temperature demanded ; con
fi
rm with OK.
Window : Output temperature - in order to change the set value press OK; with cursors
set temperature demanded ; con
fi
rm with OK.
It is possible to exit every sub- menu window in any moment without saving settings by pressing the button or .
It is possible to exit every sub- menu window in any moment without saving settings by pressing the button or .
- setting the op mode for the unit after IN external input triggering; enter edition after
pressing OK; with cursors
select an appropriate external input mode, where:
- external input function OFF;
- manual mode – temperature setting: non-freeze;
- manual mode – temperature setting: comfort;
- manual mode – temperature setting: econo;
- automatic op mode – temperature setting according to the program selected;
- manual op mode – temperature setting: output;
Con
fi
rm the selected mode by pressing OK.
Sensor adaptation setting – If there are any differences between real and measured tempera-
ture, it is possible to correct the error by means of the sensor correction:
Enter the adaptation temperature setting mode by pressing OK;
With
cursors select temperature correction within the range -4,5°C ÷ +4,5°C; con
fi
rm
selection by pressing OK.
It is possible to exit every sub- menu window in any moment without saving settings
by pressing the button or .
MAIN RESET
In order to cancel the clock system (time, date, activity of given functions etc.) you should
hold buttons ( and ) simultaneously in the main menu for
3 sec
;
All the display
fi
elds will light up;
After a while, the clock will automatically set date and time.
Attention: In order to restore factory settings, you should additionally hold button OK
CONNECTIONS
ASSEMBLY
APPLICATION
CASING DIMENSIONS
PRODUCT FAMILY
The RTM-20 regulator is a member of
the RTM product family.
1. Disconnect the electric network by me-
ans of an appropriate cut-off, current- li-
miting circuit-breaker or separator.
2. Check if there is no any voltage be-
tween power leads by means of an
appropriate gauge.
3. Mount the RTM-20 regulator on TH 35
rail.
4. Connect the system leads to the termi-
nals according to the electric diagram.
5. Connect power supply circuit.
INNER DIAGRAM
L
N
Device version:
01 - basic
20 – with the LCD
display
Device type
RTM - xx
TIME CHARTS
230 V AC mains
RTM-20
mounting
place
fl
oor
pouring 3-5 cm
pouring 1-2 cm
foamed
polystyrene
foundation
heating
cable
heating
NTC probe
in a protection pipe
The RTM-20 tempera-
ture regulator may be
used for the
fl
oor heat-
ing systems control
combined with Zamel
NTC-03 temperature
sensor.
czujnik NTC
230V
heating
junction box
μ
C
KLAW.
LCD
ZAS.
NTC
NTC
A1
A2
IN
14
12
11
A/C
RTC
IN
∆
T=1
o
C
L/N
WARRANTY CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modi
fi
cations made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.