VER. 003_20.05.2011
ROP-02 OPERATION
ROP-02 can operate in five modes for every channel:
MONOSTABLE
the relay operates only
while pressing transmit-
ter’s push-button.
BISTABLE
(one push-button) the
device changes relay
status cyclically always
after pressing the same push-
button.
SWITCH ON
the device switches on
after pressing the push-
button.
SWITCH OFF
the device switches off
after pressing the push-
button.
TIME
the device switches
off according to the
adjusted time (tp),
but it may be switched off before
adjusted time finishes. Default
settings - 15 seconds.
CAUTION! Adjusted time can
not be deleted.
RADIO TRANSMITTERS PROGRAMMING - CHANNEL 1
TIME PROGRAMMING
RADIO TRANSMITTERS PROGRAMMING - CHANNEL 2
RADIO TRANSMITTERS DELETION
COOPERATION AND OPERATING RANGE
Symbol
ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNK-04
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
P-256/8
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
P-257/4 (2)
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNM-10
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
RNP-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNP-02
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNL-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RTN-01
200 m
200 m
200 m
200 m
200 m
250 m
200 m
250 m
250 m
200 m
250 m
RCR-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RTI-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RXM-01
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
* - 1-channel transmitters do not cooperate with roller blind controllers.
CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver,
it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100% ,
glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have
also a negative influence on the range.
MONOSTABLE
mode:
BISTABLE
mode:
SWITCH ON/SWITCH OFF
mode (two push-buttons):
TIME
mode (one push-button):
An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters
is analogous.
CAUTION: Every transmitter can cooperate with ROP-02 in a different mode, depending on how they were added to
the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode.
Press transmitter’s
push-button for
a longer time.
Press the transmitter’s push-button
for a longer time. LED red diode
switches on (first signal pulsates,
next the signal is constant).
Press PROG push-button of ROP-01
device and then release it. LED red diode
switches on (first signal pulsates,
next the signal is constant).
Press and release transmitter’s first
push-button. LED red diode switches on
(first signal pulsates,
next the signal is constant).
Release transmitter’s push-
button. LED red diode switches
on (first signal pulsates, next
the signal is constant).
Release transmitter’s
push-button. LED red diode switches
on (the signal pulsates), next the LED
red diode switches off - it means the
TRANSMITTER IS ADDED.
Press and release the same transmitter’s
push-buton. LED red diode switches on
(signal pulsates) and then switches off -
THE TRANSMITTER IS ADDED.
Press and release the second transmitter’s
push-button. LED red diode switches on
(the signal pulsates) and next it switches
off - THE TRANSMITTER IS ADDED.
Press the same transmitter’s push-
-button and release it. LED red
diode switches on (the signal pulsa-
tes) and next it switches off - THE
TRANSMITTER IS ADDED.
Press PROG push-button of ROP-02 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Press PROG push-button of ROP-02 device
for a longer time until LED red diode
switches on (constant signal).
Next release PROG push-button.
Press PROG push-button of ROP-02 device
for a longer time until LED red diode
switches on (constant signal).
Next release PROG push-button.
Press PROG push-button of ROP-02 device
for a longer time till LED red diode
switches on (constant signal).
Next release PROG push-button.
CAUTION:
For the monostable mode, press the button on the remote before pressing PROG push-button.
Wait again (for about 5 seconds) till
LED red diode switches on (first signal
pulsates, next the signal is constant).
Wait again - third time (for about 5
seconds) till LED red diode
switches on (first signal pulsates,
next the signal is constant).
After the adjusted time is finished (the
number of LED red diode flashes) press
PROG push-button and then release it -
TIME IS ADDED.
After the adjusted time is finished
(the number of LED red diode flashes)
press PROG push-button and then
release it - TIME IS ADDED.
Press PROG push-button of ROP-02 device and
then release it. LED red diode switches off and
then switches on (signal pulsates). Every LED
diode pulse equals 1 second.
for
CHANNEL 1
for
CHANNEL 2
Press PROG push-button of ROP-02 device
and then release it. LED red diode switches off
and then switches on (signal pulsates). Every
LED diode pulse equals 1 second.
Maximum time is 18 hours.
Press PROG push-button of ROP-02 device for a longer time till LED red diode switches on
(constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red
diode switches on (first signal pulsates, next the signal is constant).
Press PROG push-button of ROP-02 device for a longer time until LED red diode switches
on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red
diode switches on (first signal pulsates, next the signal is constant).
Choose one of ROP-02 five operation modes
and programme the device in the same way as
for channel 1.
Press PROG push-button of ROP-02 device
for a longer time.
After 5 seconds LED red diode switches on
(signal pulsates) and then it switches off.
Release the push-button in ROP-02 -
MEMORY IS DELETED.
1s 2s
ns
1s 2s
ns