background image

RZB-04 WIRELESS CONTROL SET 

- LIGHTING, 2-CHANNEL

 

MANUAL INSTRUCTION

VER. 003_20.05.2011

APPEARANCE

FEATURES

TECHNICAL DATA

DESCRIPTION

● complete set of wireless control (4–chan-

nel button radio transmitter RNK-04 and 

2-channel radio flush receiver ROP-02). 

● 2 output relays (dry contacts 230V AC),

● lighting,  heating  operation  control,  other 

receivers control,

● easy flush installation Ø60 mm,

● 5 operation modes: switching on, switch-

ing off, monostable mode, bistable mode, 

time mode  (switch off delay),

● wide operation range (up to 200 m),

● operation is optically signalled, 

● low  current  consumption,  possibility  of 

constant operation,

● possibility of increasing operation range 

by means of RTN-01 retransmitter.

Radio  flush  receivers  are  used  both  as 

elements  in  mounting  in  flush  and  surface 

installation cable boxes and as an actuator 

built  directly  in  lighting  fitting  casings  and 

other receivers). ROP-02 enables operation 

in 5 different modes (switching on, switching 

off, monostable mode, bistable mode, time 

mode.

RNK-04

ROP-02

Input (supply) terminals:

-

L, N

Input rated voltage:

3 V DC (CR2032 battery)

230 V AC

Battery life:

3 ÷ 5 years

-

Input voltage tolerance:

-

-15 ÷ +10 %

Nominal frequency:

-

50 / 60 Hz

Nominal power consumption:

-

0,39 W („stand-by” mode) / 0,69 W 

operation mode 1 channel / 1,09 W 

operation mode 2 channels

Number of operation modes:

-

5

Number of channels:

4

2

Transmission:

radio 868,32 MHz

Coding way:

unidirectional

Coding::

addressing transmission

Maximum number of remote controls:

-

32

Range:

up to 250 m in the open area

Time adjustment:

-

1 sec÷ 18 hours (every 1 sec)

Optic signalling of transmitter’s operation:

LED red diode

Input terminals:

-

IN1, IN2

Transmitter’s input (supply) terminals:

-

OUT1, OUT2 (voltage contacts)

Relay contact parameters:

-

2NO 5A / 250V AC AC1 1250 VA

Number of terminal clamps:

-

6

Section of connecting cables:

-

up to 2,5 mm

2

Ambient temperature range:

-10 ÷ +55 

o

C

Operating position:

free

Casing mounting: wall plugs, double-sided adhesive tape

installation cable box Ø60 mm

Casing protection degree:

IP20 (EN 60529)

Protection level:

III

II

Overvoltage category:

-

II

Pollution degree:

-

2

Surge voltage:

-

1 kV (EN 61000-4-5)

Dimensions:

90 x 80 x 11,5 mm

47,5 x 47,5 x 20 mm

Weight:

0,038 kg

0,039 kg

Reference standard:

ETSI EN 300 220-1,  

ETSI EN 300 220-2

EN 60669, EN 60950, 

EN 61000

Optic signalling of receiver’s operation
Programming push-button

Input terminals (IN1, IN2)

Output terminals (OUT1, OUT2)

Input (supply) terminals (L, N)

Optic signalling  
of transmitter’s operation

Push-buttons

The  device  is  designed  for 

single-phase  installation  and 

must be installed in accord-

ance  with  standards  valid  in  

a  particular  country.  The  de-

vice  should  be  connected 

according  to  the  details  in-

cluded  in  this  operating  manual.  Installation, 

connection and control should be carried out by  

a qualified electrician staff, who act in accord-

ance  with  the  service  manual  and  the  device 

functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then. Be-

fore  installation make sure the connection ca-

bles are not under voltage. The cruciform head 

screwdriver 3,5 mm should be used to instal the 

device.  Improper  transport,  storage,  and  use 

of  the  device  influence  its  wrong  functioning.  

  It is not advisable to instal the device in the 

following cases:  if any device part is missing or 

the device is damaged or deformed. In case of  

improper functioning of the device contact the 

producer.

CAUTION!

The symbol means selective 

collecting of electrical and electronic 

equipment.  

It is forbidden to put the used 

equipment together with other waste.

WARRANTY CARD

There is 24 months guarantee on the product

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances  

b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-

TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting 

from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device 

in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy 

between the goods and the contract.

Salesman stamp and signature, date of sale

CONNECTION

APPLICATION

CAPACITY

750W

250W

500W

375W

ROP-02 MOUNTING

1. Disconnect power supply by the phase fuse, 

the circuit-breaker  or the switch-disconnector 

combined to the proper circuit.

2. Check if there is no voltage on connec-

tion cables by means of a special measure 

equipment.

3. Connect  the cables with the terminals in ac-

cordance with the installing diagram.

4. Install ROP-02 device in installation cable box.

5. Switch on the power supply from the mains.

RNK-04 FUNCTIONING, MOUNTING

By pressing the button, the transmitter sends  

a signal with 868,32 MHz frequency which con-

trols EXTA FREE receivers. 

Device program-

ming procedure (adding a transmitter to  

a receiver’s memory) is described in par-

ticular EXTA FREE manual instructions.

 

The device  range (up to 250 m depending on 

a receiver) can be increased by means of a re-

transmitter or few RTN-01 retransmitters. The 

device can be mounted in any place by means 

of double-sided adhesive tape or wall plugs  

5 x (3 x 30) mm.

Mounting by means of wall plugs:

1. Remove the button - to do it press the but-

ton on one side, and on the other side put  

a screwdriver into a slot and lift up the button.

2.  Find  a  place  on  the  wall  to  mount  the 

transmitter, make two holes corresponding 

mounting holes from the transmitter’s base.

3. Set wall plugs in the holes.

4. Fix the base by means of screwing screws 

into wall plugs.

5. Place the button again.

BATTERY CHANGE

Battery discharge status is signalled by 

several  LED  red  diode  flashes  during 

transmission time.

1. Remove the button (mounting - point 1).

2.  By  means  of  a  screwdriver  lever  up  the 

printed-circuit  board  releasing  the  bottom 

latch and remove it from the base.

3. Remove the battery from the latch.

4. Mount a new battery. Watch battery polari-

sation marked on the latch. Wrong battery 

mounting may cause device damage.

5. Put the removed printed-circuit board back  

in the base.

6. Put back the button.

CAUTION: While changing the battery, 

 

it is suggested to press any of the buttons 

for about 5 seconds before putting it into 

a latch. Next press transmission button 

several times to check its operation. If the 

transmitter does not work properly repeat 

the battery change procedure.

2-channel radio flush receiver ROP-02 

operates as a receiver of 8-channel remote 

controller P-256/8 and of 4-channel button 

radio transmitter RNK-04 (light sources 

switch on/switch off control). The above 

mentioned transmitters can also control 

operation of radio lighting switch RWL-01 

and remote control socket RWG-01.

The ZAMEL company devices 

which are characterised  

with this sign can cooperate 

with each other.

Отзывы: