RZB-04 WIRELESS CONTROL SET
- LIGHTING, 2-CHANNEL
MANUAL INSTRUCTION
VER. 003_20.05.2011
APPEARANCE
FEATURES
TECHNICAL DATA
DESCRIPTION
● complete set of wireless control (4–chan-
nel button radio transmitter RNK-04 and
2-channel radio flush receiver ROP-02).
● 2 output relays (dry contacts 230V AC),
● lighting, heating operation control, other
receivers control,
● easy flush installation Ø60 mm,
● 5 operation modes: switching on, switch-
ing off, monostable mode, bistable mode,
time mode (switch off delay),
● wide operation range (up to 200 m),
● operation is optically signalled,
● low current consumption, possibility of
constant operation,
● possibility of increasing operation range
by means of RTN-01 retransmitter.
Radio flush receivers are used both as
elements in mounting in flush and surface
installation cable boxes and as an actuator
built directly in lighting fitting casings and
other receivers). ROP-02 enables operation
in 5 different modes (switching on, switching
off, monostable mode, bistable mode, time
mode.
RNK-04
ROP-02
Input (supply) terminals:
-
L, N
Input rated voltage:
3 V DC (CR2032 battery)
230 V AC
Battery life:
3 ÷ 5 years
-
Input voltage tolerance:
-
-15 ÷ +10 %
Nominal frequency:
-
50 / 60 Hz
Nominal power consumption:
-
0,39 W („stand-by” mode) / 0,69 W
operation mode 1 channel / 1,09 W
operation mode 2 channels
Number of operation modes:
-
5
Number of channels:
4
2
Transmission:
radio 868,32 MHz
Coding way:
unidirectional
Coding::
addressing transmission
Maximum number of remote controls:
-
32
Range:
up to 250 m in the open area
Time adjustment:
-
1 sec÷ 18 hours (every 1 sec)
Optic signalling of transmitter’s operation:
LED red diode
Input terminals:
-
IN1, IN2
Transmitter’s input (supply) terminals:
-
OUT1, OUT2 (voltage contacts)
Relay contact parameters:
-
2NO 5A / 250V AC AC1 1250 VA
Number of terminal clamps:
-
6
Section of connecting cables:
-
up to 2,5 mm
2
Ambient temperature range:
-10 ÷ +55
o
C
Operating position:
free
Casing mounting: wall plugs, double-sided adhesive tape
installation cable box Ø60 mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III
II
Overvoltage category:
-
II
Pollution degree:
-
2
Surge voltage:
-
1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,038 kg
0,039 kg
Reference standard:
ETSI EN 300 220-1,
ETSI EN 300 220-2
EN 60669, EN 60950,
EN 61000
Optic signalling of receiver’s operation
Programming push-button
Input terminals (IN1, IN2)
Output terminals (OUT1, OUT2)
Input (supply) terminals (L, N)
Optic signalling
of transmitter’s operation
Push-buttons
The device is designed for
single-phase installation and
must be installed in accord-
ance with standards valid in
a particular country. The de-
vice should be connected
according to the details in-
cluded in this operating manual. Installation,
connection and control should be carried out by
a qualified electrician staff, who act in accord-
ance with the service manual and the device
functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Be-
fore installation make sure the connection ca-
bles are not under voltage. The cruciform head
screwdriver 3,5 mm should be used to instal the
device. Improper transport, storage, and use
of the device influence its wrong functioning.
It is not advisable to instal the device in the
following cases: if any device part is missing or
the device is damaged or deformed. In case of
improper functioning of the device contact the
producer.
CAUTION!
The symbol means selective
collecting of electrical and electronic
equipment.
It is forbidden to put the used
equipment together with other waste.
WARRANTY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
Salesman stamp and signature, date of sale
CONNECTION
APPLICATION
CAPACITY
750W
250W
500W
375W
ROP-02 MOUNTING
1. Disconnect power supply by the phase fuse,
the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3. Connect the cables with the terminals in ac-
cordance with the installing diagram.
4. Install ROP-02 device in installation cable box.
5. Switch on the power supply from the mains.
RNK-04 FUNCTIONING, MOUNTING
By pressing the button, the transmitter sends
a signal with 868,32 MHz frequency which con-
trols EXTA FREE receivers.
Device program-
ming procedure (adding a transmitter to
a receiver’s memory) is described in par-
ticular EXTA FREE manual instructions.
The device range (up to 250 m depending on
a receiver) can be increased by means of a re-
transmitter or few RTN-01 retransmitters. The
device can be mounted in any place by means
of double-sided adhesive tape or wall plugs
5 x (3 x 30) mm.
Mounting by means of wall plugs:
1. Remove the button - to do it press the but-
ton on one side, and on the other side put
a screwdriver into a slot and lift up the button.
2. Find a place on the wall to mount the
transmitter, make two holes corresponding
mounting holes from the transmitter’s base.
3. Set wall plugs in the holes.
4. Fix the base by means of screwing screws
into wall plugs.
5. Place the button again.
BATTERY CHANGE
Battery discharge status is signalled by
several LED red diode flashes during
transmission time.
1. Remove the button (mounting - point 1).
2. By means of a screwdriver lever up the
printed-circuit board releasing the bottom
latch and remove it from the base.
3. Remove the battery from the latch.
4. Mount a new battery. Watch battery polari-
sation marked on the latch. Wrong battery
mounting may cause device damage.
5. Put the removed printed-circuit board back
in the base.
6. Put back the button.
CAUTION: While changing the battery,
it is suggested to press any of the buttons
for about 5 seconds before putting it into
a latch. Next press transmission button
several times to check its operation. If the
transmitter does not work properly repeat
the battery change procedure.
2-channel radio flush receiver ROP-02
operates as a receiver of 8-channel remote
controller P-256/8 and of 4-channel button
radio transmitter RNK-04 (light sources
switch on/switch off control). The above
mentioned transmitters can also control
operation of radio lighting switch RWL-01
and remote control socket RWG-01.
The ZAMEL company devices
which are characterised
with this sign can cooperate
with each other.