SUGGESTED CABLE TYPES AND ACCEPTABLE INSTALLATION LENGTHS
Note:
1. L1: Distance from monitor to power, L2: Distance from panel to power.
2. The same BUS should use the same wire with the same specification.
Cable
type
1
monitor
2
monitors
3
monitors
4
monitors
5
monitors
6
monitors
7
monitors
8
monitors
9
monitors
10
monitors
1 panel
2 panels
3 panels
4 panels
5 panels
6 panels
7 panels
8 panels
L1 max [m]
L2 max [m]
UTP CAT5
135
70
45
-
-
-
-
-
-
-
235 120
80
60
45
-
-
-
UTP CAT6
175
90
60
45
-
-
-
-
-
-
300 150 100
75
60
50
-
-
YTLY
2x 0,2 mm²
135
70
45
-
-
-
-
-
-
-
235 120
80
60
45
-
-
-
YTLY
2x 0,3 mm²
220 110
75
55
-
-
-
-
-
-
300 185 125
90
70
60
50
-
RVV / LiYCY
2x 0,5 mm²
300 180 120
90
75
60
50
-
-
-
300 300 210 150 120 100
85
75
RVV / LiYCY
2x 0,75 mm²
300 260 170 130 100
85
75
65
55
50
300 300 290 210 170 140 120 100
RVV / LiYCY
2x 1 mm²
300 300 260 190 150 130 110
95
85
75
300 300 300 300 260 210 180 160
POWER SUPPLY OF THE ELECTRIC LOCK THROUGH THE SIGNAL
DISTRIBUTOR VP-SW2
Attention:
The +12 V and GND connectors support magnetic locks and electric strikes operating in the range
of (≤) 12 V 0.5 A, 6 W. The relay opening time is defined from the monitor settings. If the given
values are exceeded, damage may occur to both the magnetic lock, electric strike and the relay.
IN
P
U
T:
10
0 ÷ 2
40 V A
C
Electric lock
Panel 1
Black:
LOCK NO
Green:
LOCK COM
Orange:
LOCK NC
Yellow:
GATE NO
White:
GATE COM
Red:
BUS
Blue:
BUS
CH1
CH2
+12 V
GND
1
1
2
2
V
P-
SW
2
Si
gn
al
D
is
tribu
to
r