The boom that turns off when the speed setting is reached can be changed in either the hidden settings
screen, or with the FastICE system programming tool and software.
Safety and Functional Interlocks
The hydraulically driven water pump is interlocked to the ice-making water tank level sensor to prevent the
pump from running dry. When the level sensor indicates tank levels below 0% for 2 seconds, the ice
making water pump will automatically shut off.
Likewise, if the control system does not sense a water level greater than 0%, the water pump will not start.
A moving average calculation is performed on the water level sensor signal to prevent rapid off/on due to
water sloshing in the tank.
Re-filling the tank so the level holds above 0% for at least 5 seconds will reset this interlock and allow the
pump to start.
Operating Manual
Zamboni FastICE
®
Operating Manual
DK - 11000
Page 15 of 44