ZALMAN RESERATOR2 Скачать руководство пользователя страница 2

RESERATOR 2

2

The specifications of any product may change without prior notice to improve performance.

1. Make sure that the power source’s output voltage and frequency are compatible with

the power input requirements of the water pump before installing (input voltage and 

frequency of the water pump are shown on the box). 

2. Do not place in dusty or humid conditions, under direct sunlight, or near a heat source

such as a room heater. 

3. Do not drop or subject it to excessive force. 

4. CPU socket compatibility must be checked. 

5. Familiarize yourself with this manual.

6. Do not mix any contaminant with the coolant when filling, for it may cause product failure. 

7. Check for leaks on Water Blocks before installation. 

Installation Notes

1. Reserator 2 simultaneously operates with the PC. The power must first be supplied to 

the AC power cable before turning on the PC because it uses an AC pump. 

2. Place the Reserator 2 and the PC body at the same location for use.

3. If the coolant isn’t circulating properly, or if the pump flux becomes too low, then the 

red blinkers will flash as well as warning sound. In this case, turn the PC OFF immediately. 

4. Do not place any objects on the product. 

5. Install on a flat surface with no vibration or slant, and do not tilt or lay horizontally. 

6. Use distilled water with the coolant, regularly check the amount of coolant, and replenish

as needed (must be replenished every year).

7. If a leak is found, turn off the system immediately, and contact the place of purchase

or ZALMAN. 

8. If the system will not be used for an extended period of time, then turn the Water

Pump OFF. 

9. When moving the system, separate the Reserator from the PC case before moving. 

10. Do not let any air bubbles form inside the Water Block and the tubes during operation. 

11. Always make sure that the Water Pump is functioning properly. 

12. If the power supply cord is damaged, it must be replaced by the manufacturer, its

service agent, or a similarly qualified person in order to avoid a hazard.

Operational Notes

Installation and Operational Notes

Содержание RESERATOR2

Страница 1: ...and watch the Reserator 2 installation video for an installation overview Pleasereadthismanualthoroughlybeforeinstallation Thespecificationsofthisproductanditscomponentsmaychangewithoutpriornoticetoi...

Страница 2: ...PC body at the same location for use 3 If the coolant isn t circulating properly or if the pump flux becomes too low then the red blinkers will flash as well as warning sound In this case turn the PC...

Страница 3: ...ficiency heatsink in the middle section and a water tank and water pump in the back section which allows easy installation and use The anodized product and the provided coolant prevents corrosion The...

Страница 4: ...t provide freedom in direction when connecting them with the tubes which further allows simple installation 1 4 Northbridge Water Block ZM NWB1 Optional This anodized pure aluminum block is built for...

Страница 5: ...sions 63 L x 63 W x 16 5 H mm 4 Compatibility Intel Pentium 4 Socket 775 478 AMD Sempron AMD64 Athlon 64 Athlon 64 FX Opteron Socket 754 939 940 2 3 VGA Water Block ZM GWB3 1 Weight 100 g 2 Material A...

Страница 6: ...e specifications of any product may change without prior notice to improve performance 3 Installation Overview DC Cable Power Supply 4 Pin Connecter CPU Water Block VGA Water Block I O Bracket Quick C...

Страница 7: ...r Block ZM WB4 Gold 1SET Please refer to the separately provided manual for the ZM WB4 Gold 4 3 VGA Water Block ZM GWB3 1SET Please refer to the separately provided manual for the ZM GWB3 4 6 Coolant...

Страница 8: ...aluminum block is built for high performance cooling and is designed for Motherboard compatibility with a wide variety of northbridge chipsets VGA RAM Water Block ZM RWB1 This VGA RAM Water Block is...

Страница 9: ...the bottom of the Reserator with the use of Bolts 5 3 Fill the Coolant 1 TakeofftheReseratorCoverafterunscrewing its Bolts 2 Fill with the provided coolant ZM G300 250 and one liter of distilled water...

Страница 10: ...t off the direct current and wait for the impeller to stop Once the impeller has come to a complete halt you must restart it in order to entirely eliminate the internal air 6 If the coolant is not cir...

Страница 11: ...onnect the VGA Water Blcok with Reserator s Base IN 1 Connect one end of the PVC Tube to the VGA Water Block Fitting and fasten with a Tube Clamp as shown in the diagram 2 Pull out the PVC Tube throug...

Страница 12: ...not exert excessive force when connecting the connector Slowly connect with two hands 5 11 Installing the Northbridge Water Block 1 To install the Northbridge Water Block connect as shown in the diag...

Страница 13: ...heReserator sReservoir andfillitbyapproximately70 3 Connect the power supply s 4 Pin connector to the Reserator s DC cable connector and provide power for the Power Supply by switching its ON OFF butt...

Страница 14: ...pply s 4 Pin connector 5 16 Front Panel Controller Functions 1 Flux Check Warning sound will go off and the red LED will flicker when the flux falls below a certain level due to a problem in pump leak...