Страница 1: ...se read this manual completely PA2184B Indirect Speaker Selector FEATURES l 2CH inputs 10CH outputs l Hi Low alarm level available l The channel will be switched to input B automatically while alarming l Alarm indicator and output indicator ...
Страница 2: ...2 Left blank for memo ...
Страница 3: ...1 25 COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Power switch 1 is power on and the power LED is on Power LED indicator Switch indicator Output indicator Switching key ALM OUTPUT to Timer Siren Device Emergency from FIRE center Power Amp B PA series for EMC Power Amp A PA series for BGM Input level preset ...
Страница 4: ...switch channels which you want 4 An grounded Alarm signal will be sent out from ALARM OUT while any alarm signal appears on ALARM INPUT SPECIFICATIONS Channels 10 switchable Input capacity 70 100 V 10 A Output capacity 70 100 V 5 A CH ALM 10 CHs 5 24 V 0 according to presetting Protection AC fuse 1 Power Requirement AC 220 240 V 50 60 Hz Dimensions 485 88 378 mm Gross weight 6 5 kg Net weight 5 2 ...