![Z3 Technology Z3Cam-DX Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/z3-technology/z3cam-dx/z3cam-dx_user-instructions_916634049.webp)
Z3Cam-DX User Instructions
DOC-USR-0152-04
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
49
(4)
Set the
TCP Port
to
1000
. This value must match the
VISCA Control TCP Port
value listed in the
Camera tab of the Z3Cam-DX user interface.
(5)
Assign a
COM Port
that is not currently in use on your system using the dropdown menu.
(6)
Click the
Connect
button. The application will minimize. Do not close this application while your
camera control is in use.
The COM port selected will now redirect data to the Z3Cam-DX.
If the camera is rebooted or power cycled, you will need to reconnect COM2TCP on your PC. COM2TCP
does
not
automatically detect the dropped connection.
7.4.2
Camera Controller Software
(7)
Install your camera control software onto your PC.
(8)
Launch the controller software application.
(9)
Set the port name to match the
COM Port
selected previously.
(10)
Set the
Baud Rate
to
9600
.
(11)
Save these settings.
(12)
Remember, you may need to close and restart your camera controller application for changes to
take effect.
Figure 46 Com2TCP Configuration
Set to “1000”
Set to the IP
Address of
Your Z3 Unit
Figure 47 Camera Controller Software Configuration
Com2TCP
Camera Control Software
Match Values
Set to
“9600kbps”