Blocks wakeup even when wakeup interval is set (Parameter Number 25, Parameter Size 1) If the KFOB 
wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery

Value

Description

0

Wakeup is blocked (Default)

1

Wakeup is possible if configured accordingly.

Send unsolicited Battery Report on Wake Up (Parameter Number 30, Parameter Size 1) 

Value

Description

0

No (Default)

1

To same node as wake up notification

2

Broadcast to neighbours

Technical Data

IP Rating

IP 20

Battery Type

1 * CR2032

Frequency

868.42 MHz (SRD Band)

Wireless Range

up to 100 m outside, on average up to 20 m inside buildings

Explorer Frame Support Yes

SDK

4.55.00

Device Type

Slave with routing capabilities

Generic Device Class

Remote Switch

Specific Device Class

Multilevel Remote Switch

Routing

No

FLiRS

No

Firmware Version

1.4

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 10 

Содержание ZME_KFOB2

Страница 1: ...cription 1 The Z Wave Me Key Fob is a 4 button Z Wave device that can both control other Z Wave devices and activate predefined scenes in a controller or IP Gateway Although it is controlling other de...

Страница 2: ...of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This co...

Страница 3: ...of associated devices with only On Off commands Devices are controlled using only Basic Set On Off commands On dimming Up event On is sent on dimming Down Off is sent This mode also implements commun...

Страница 4: ...de MUST be turned on wirelessly However in protected by sequence mode it is possible to unlock the device for local operation by pressing any button within 5 sec The unlock state will last for 5 secon...

Страница 5: ...he technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node...

Страница 6: ...e within 20 sec A common way is hitting a control button one or three times Please consult the manual of the device to be controlled for more information how to issue an Node Information Frame Any but...

Страница 7: ...n Off only mode On command is sent on Dim Up Off on Dim Down In Scenes mode the scene ID sent is 10 group ActionID where ActionID is 1 On 2 Off 3 Dim Up Start 4 Dim Down Start 5 Dim Up Stop 6 Dim Down...

Страница 8: ...own Start 5 Dim Up Stop 6 Dim Down Stop Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes...

Страница 9: ...ts Default 50 Send the following Switch All commands Parameter Number 21 Parameter Size 1 Value Description 1 Switch off only Default 2 Switch on only 255 Switch all on and off Invert buttons Paramete...

Страница 10: ...ue Description 0 No Default 1 To same node as wake up notification 2 Broadcast to neighbours Technical Data IP Rating IP 20 Battery Type 1 CR2032 Frequency 868 42 MHz SRD Band Wireless Range up to 100...

Отзывы: