background image

11-11-2014

manuals.zwaveeurope.com/make.php?lang=en&type=&sku=ZME_WALLC-S

http://manuals.zwaveeurope.com/make.php?lang=en&type=&sku=ZME_WALLC-S

1/8

ZME_WALLC-S
Z-Wave Secure Wall Controller

Firmware Version : 1.0

Quick Start

S

 This device operates as Z-Wave sensor in two modes: the normal control mode (daily use) or in management mode for setup. Pushing all

four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED). The management mode will time out after 10
seconds if no further button is pushed. Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate
inclusion on the device by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the
LEDs until the timeout occurs after 10 seconds. A short press of any buttons also terminates this mode. Re-Inclusion and Exclusion are
performed by pushing button 1 in management mode. In this mode button 2 issues a Node Information Frame or wakeup notification and button
4 is used to add devices into association groups. The device supports secure communication.

Please refer to the chapters below for detailed information about all aspects of the products usage.

What is Z-Wave?

This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the international standard for wireless
communication in smart homes and buildings. It is using the frequency of 868.42 MHz to realize a very stable and secure communication. Each
message is reconfirmed (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case
the receiver is not in direct wireless range of the transmitter.

Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) transmitting metered or measured data or actuators (A) capable to
execute an action. Controllers are either static mains powered controllers (C) also referred to as gateways or mobile battery operated remote
controls(R). This results in a number of possible communication patterns within a Z-Wave network that are partly or completely supported by a specific
device.

1.  Controllers control actuators
2.  Actuators report change of status back to controller
3.  Sensors report change of status of measured values to controller
4.  Sensors directly control actuators
5.  Actuators control other actuators
6.  Remote controls send signals to static controllers to trigger scenes or other actions
7.  Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is
managing the network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other controllers don't
manage the network itself but can control other devices. They are called secondary controllers. The image also shows that its not possible to operate a
sensor just from a remote control. Sensors only communicate with static controllers.

Product description

The Z-Wave.Me Wall Controller is a Z-Wave device that can both control other Z-Wave devices and activate predefined scenes in an IP gateway.
Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-
Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration
parameters:

1.  Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands.
2.  Activation of predefined scenes in Gateways or other Z-Wave devices.

The wall controller must be completed by a mounting frame, the wall switch frame and a rocker. They are not scope of delivery of this device.

This device support secure communication when included by a controller that also supports secure communication. The device will then send all
commands as secure commands unless the receiving device can not accept them. Then the command is send the normal way automatically.

The device will be completed with different designs of wall frame and rockers.

Содержание ZME WALLC-S

Страница 1: ...referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific device 1 Controllers control actuators 2 Actuators report change of status back to controller 3 Sensors report change of status of measured values to controller 4 Sensors directly control actua...

Страница 2: ...n or exclusion attempt is confirmed by hitting this button Any button press stops the mode as well Button 2 Send Node Information Frame and Wake up Notification see explanation below Button 3 Factory Default Reset After clicking on button 3 keep button 4 pushed for 4 seconds Button 4 Enter into Association mode to assign target devices to one of the four association Refer to the manuals section ab...

Страница 3: ...ous scene activation commands to a central controller Operating modes for direct device control are Direct Control of associated devices with On Off Dim commands parameter 11 14 1 Devices are controlled using Basic Set On Off commands and SwitchMultilevel Dim Start Stop This mode implements communication pattern 7 Direct Control of associated devices with only On Off commands parameter 11 14 2 Dev...

Страница 4: ...l wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification The controller can then empty the mailbox Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff b...

Страница 5: ...e controlled for more information how to issue an Node Information Frame Any button press on Wall Controller at this stage will terminate the process Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow to configu...

Страница 6: ...Number 13 Parameter Size 1 This parameter defines the command to be sent to devices of control group C when the related button is pressed Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes 7 Control Door Lock 8 Central Scene to Gateway Default Command to Control Group D...

Страница 7: ... Parameter Number 30 Parameter Size 1 Value Description 0 No 1 To same node as wake up notification Default 2 Broadcast to neighbors Command Classes Supported Command Classes Battery version 1 Wake Up version 2 Association version 2 Version version 2 Scene Controller Configuration version 1 Multi Channel Association version 2 Multi Command Encapsulated version 1 Configuration version 1 Manufacture...

Страница 8: ...Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a ...

Отзывы: