The function of auto inclusion will be executed as long as the in wall switch does not 

have Node ID and just connect the switch to main power. 

 

Note: Auto inclusion timeout is 2 minute during which the node information of 

explorer frame will be emitted once every several seconds. Unlike “inclusion” function 

as shown in the table below, the execution of auto inclusion is free from pressing the 

On/Off button on the Switch. 

 

The table below lists an operation summary of basic Z-Wave functions. Please refer 

to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to include/exclude/associate devices 

 

Function 

Description 

Annotation

 

No node ID 

The Z-Wave Controller does not allocate 
a node ID to the Switch. 

LED 2-second on, 2-second 
off

 

Inclusion 

1.  Put your Z-Wave controller into 

inclusion mode by following the 
instructions provided by the 
controller manufacturer. 

One press one flash LED

 

2.    Pressing Include button of PAN05 

three times within 2 seconds will 
enter inclusion mode.

 

Exclusion 

1.  Put your Z-Wave controller into 

exclusion mode by following the 
instructions provided by the 
controller manufacturer. 

One press one flash LED

 

1.  Pressing Include button of PAN05 

three times within 2 seconds will 
enter exclusion mode. 

Node ID has been excluded. 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Reset 

1.  Pressing Include button of PAN05 

three times within 2 seconds will 
enter inclusion mode. 

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable.

 

2.  Within 1 second, press Include 

button of PAN05 again for 5 
seconds. 

3.  IDs are excluded. 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Association 

1.  The PAN05 is an always listening 

Z-Wave device, so associations 
may be added or removed by a 
controller at any time. 

Or    If your controller requires to have 

the PAN05 send a 'node information 
frame' or NIF for associations, then 
pressing the On/Off button three 
times within 2 seconds will cause 
the PAN05 to send its NIF.

 

 

2.    There are only one group for the 

switch 

 

Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a node 
ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 

Sometimes people are not easy to execute exclusion or inclusion especially when 
PAN05 already installed in a wall box. To solve this issue, PAN05 support a special 
feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” 
at the first 3 minutes when first time connect to main power.

 

 

 

 
LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification. 
 

State Type 

LED Indication

 

Normal 

Whenever we switch On and off of the PAN05 by S1 S2 or On/Off 
button or RF command, the LED will lights up when switch on; 
whereas LED off when switch off.

 

No node ID 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second 
intervals. By pressing S1 S2 or On/Off button, it will stop flashing 
temporarily.

 

Learning 

When PAN05 is in learning mode, LED flashes on and off 
alternately and repeatedly at 0.5 second intervals.

 

Overload 

When overload state occurs, the Switch is disabled of which LED 
flashes on and off alternately at 0.2 second intervals. Overload 
state can be cleared by disconnect and reconnect the Switch to the 
main power.

 

Содержание PAN05-1B

Страница 1: ...witch Load On and Off one main application is the light control If connect the COM terminal directly to AC Line terminal the new smart relay calibration technology can reduce the inrush current caused...

Страница 2: ...ds 3 IDs are excluded 0 5s On 0 5s Off Enter auto inclusion Association 1 The PAN05 is an always listening Z Wave device so associations may be added or removed by a controller at any time Or If your...

Страница 3: ...spond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basi...

Страница 4: ...On Off mode 1 0 1 1 0 Disable manual On Off 1 Enable manual On Off 4 LED indication mode 1 1 3 1 1 Show switch state 2 Show night mode 3 One flash mode 5 Auto off timer 1 0 0x7F FF Second 0 0 Disable...

Страница 5: ...unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pr...

Страница 6: ...ference Statement FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are desig...

Страница 7: ...7 operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter...

Отзывы: