Reading from clamp on Current Transformer Cable CT-1 is reported to Meter Channel 1
Reading from clamp on Current Transformer Cable CT-2 is reported to Meter Channel 2.
Whenever the Clamp’s energy output changes by +/- 2W, the Clamp Meter will automatically transmit
a signal with power consumption data to the Z-Wave network coordinator for update.
The Clamp Meter transmits a signal with power data to coordinator whenever accumulated power
usage of the clamp increases by 0.1kW/hr.
The Clamp has an accuracy of +/- 5%.
To clear the clamp of its accumulated power consumption data, follow steps below:
1.
Un-plug AC cable to power down Clamp Meter.
2.
Press and hold the function button, while holding the button, power on the Clamp Meter by
re-plug in the AC cable.
3.
Release the function button when red LED starts to quickly flash.
4.
Un-plug and re-plug AC cable again, clearing is complete.
Maximum Operation Load
110V: 6600W and 60A
230V: 13800W and 60A.
Z-Wave Information
Device Type:
Whole Home Meter - Simple
Role Type:
Always On Slave (AOS)
Command Class Support/Control
Mandatory CC Support: Association CC, v2
Association Group Information CC
Device Reset Locally CC
Manufacturer Specific CC, v2
Meter CC,
Version CC, v2
Z-Wave Plus Info CC, v2
Power Level CC,
Firmware Update CC, v2
Z-Wave’s Groups (Association Command Class Version 2)
Group 1 for “LifeLine”:
Device Reset Locally CC
Meter CC