![Z-Wave 5430499 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/z-wave/5430499/5430499_installation-manual_3095403004.webp)
With this function the thermostat can control other heating
devices such as an electric radiator or an electric fan. Remember
to use association group 2, when you enable the associations.
Maximum 8 devices per thermostat.
NOTE
Wooden floor requires that the use of a max temperature
floor sensor is connected. The floor temperature should be
limited to 27°C.
In order to run some schedule or week program, the primary
controller/gateway should be responsible for controlling the
thermostat using those selected command classes.
Classes:
GENERIC_TYPE_THERMOSTAT
SPECIFIC_TYPE_SETPOINT_THERMOSTAT
COMMAND_CLASS_BASIC
COMMAND_CLASS_THERMOSTAT_SETPOINT_V3
COMMAND_CLASS_THERMOSTAT_SETBACK
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_ASSOCIATION
+ All other mandatory classes for selected device type
DESCRIPTION
Temperature range
+5°C/+40°C
Displayed temperature
-30°C 60°C
Floor min. limit
5°C (5°C 35°C)
Floor max. limit
35°C (5°C 35°C)
Air min. limit
5°C (5°C 40°C)
Air max. limit
35°C (5°C 40°C)
Regulator min. limit
0 (0 9)
Hysteresis
0,3°C - 3,0°C
Default hysteresis
0,5°C
CO set point
21°C (5°C 40°C)
ECO set point
18°C (5°C 40°C)
Power regulator
P02 (P00 P10) cycle of 30 minutes
Temperature setback
Adjustable within temperature range
Temperature setback activation
Pilot wire/Z-Wave user interface
Thermo-Floor AS can
not be held liable for
typographical errors, other
errors or omittances in
our information.
Product specifications
may change without
further notice.
All electrical installations
must be carried out by a
licensed electrician.
The product must be installed
in accordance with national
building codes and our
installation guides.
Thermo-Floor AS l Østre Totenvei 24, NO-2816 Gjøvik, NORWAY