Z-Wave 5430499 Скачать руководство пользователя страница 4

With this function the thermostat can control other heating 
devices such as an electric radiator or an electric fan. Remember 
to use association group 2, when you enable the associations. 
Maximum 8 devices per thermostat. 

NOTE 

 Wooden floor requires that the use of a max temperature 

floor sensor is connected. The floor temperature should be 
limited to 27°C.

In order to run some schedule or week program, the primary 
controller/gateway should be responsible for controlling the 
thermostat using those selected command classes.

Classes:
GENERIC_TYPE_THERMOSTAT
SPECIFIC_TYPE_SETPOINT_THERMOSTAT

COMMAND_CLASS_BASIC
COMMAND_CLASS_THERMOSTAT_SETPOINT_V3
COMMAND_CLASS_THERMOSTAT_SETBACK
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_ASSOCIATION
+ All other mandatory classes for selected device type

DESCRIPTION

Temperature range

+5°C/+40°C

Displayed temperature

-30°C   60°C

Floor min. limit

5°C (5°C   35°C)

Floor max. limit

35°C (5°C   35°C)

Air min. limit

5°C (5°C   40°C)

Air max. limit

35°C (5°C   40°C)

Regulator min. limit

0 (0   9)

Hysteresis

0,3°C - 3,0°C

Default hysteresis

0,5°C

CO set point

21°C (5°C   40°C)

ECO set point

18°C (5°C   40°C)

Power regulator

P02 (P00   P10) cycle of 30 minutes

Temperature setback 

Adjustable within temperature range 

Temperature setback activation

Pilot wire/Z-Wave user interface

Thermo-Floor AS can  
not be held liable for  

typographical errors, other  

errors or omittances in  

our information.

Product specifications  

may change without  

further notice. 

All electrical installations  

must be carried out by a  

licensed electrician.

The product must be installed  

in accordance with national  

building codes and our  

installation guides.

Thermo-Floor AS   l   Østre Totenvei 24, NO-2816 Gjøvik, NORWAY  
Phone: +47 61 18 77 77    l   [email protected] – www.heatit.com