PRINCIPLES FOR REGULATION

The Heatit Z-Wave is designed for controlling electrical heating 
cables and electrical radiators/convectors. The thermostat 
has 2 internal temperature sensors and has 3 algorithms for 
temperature compensation.
After you have set the temperature, the thermostat will use 
a hysteresis to regulate the temperature. The hysteresis is 
adjustable.

TEMPERATURE SHOWN IN DISPLAY

The temperature shown in the display is the actual temperature 
for fl oor sensor and the external room sensor. You are able to 
calibrate the sensor values.
When using the internal room sensor, the temperature shown is 
the set point. Due to the internal heat buildup in the thermostat, 
we do not recommend to use this function. This makes the 
thermostat sensitive towards draft in the connection box.

If the thermostat is to be used with waterbased heating systems, 
you have to use an external sensor.

Z-WAVE THERMOSTAT – SETUP

This manual describes the most essential functions and 
technical specifi cations of the thermostat. 
These instructions help the user to control the thermostat, and 
the electrician to install and setup the thermostat.

INSTALLATION

Installation must be done by a qualifi ed Electrical Installer in 
accordance with the National Building codes. Before installation, 
disconnect any power to the thermostat’s mains. During 
installation of the thermostat, power to the thermostat must be 
disconnected AT ALL TIMES!

Use e.g. a small slotted screwdriver. The front cover and the 
frame can now be removed. 

Now connect the wires to the thermostat’s terminals:

HEATING (N)  

Heating cable connection (Neutral)

N  

 

Power connection (Neutral) 230V

L  

 

Power connection (Live) 230V

HEATING (L)  

Heating cable connection (Live)

PILOT  

 

230V pilot signal

FLOOR SENSOR  

NTC type (10, 12, 15, 33 or 47kΩ). Default 10kΩ.

EXTERNAL SENSOR 

 NTC type (10, 12, 15, 33 or 47kΩ). Default 10kΩ.

Next, position the thermostat and fasten it onto the wall’s 
mounting box using 2-4 screws. Position the frame, then 
position and carefully press the front cover until it snaps in 
place. Check that the front cover has snapped in place properly 
on both left and right side. The front cover should now be fi rmly 
fi xed on all sides.

·

 DISPLAY

   LED-display 3x 7-Seg 13.2mm CA white

STARTUP

AFTER CONNECTING THE POWER TO THE THERMOSTAT FOR THE 
FIRST TIME, ALL PARAMETERS WILL DEFAULT SETTINGS.

2 yr

HEATIT Z-WAVE

      

Installation guide

SW 1.7

 

Made in EU

TF 021

HE

ATING L

 L

N

HE

ATING N

PIL

OT

 WIRE

FLOOR

SENSOR

EXTERNAL