Issued: 01/21/10 REV 50
Doc# 27-0042UM
20
21
Issued: 01/21/10 REV 50
Doc# 27-0042UM
1. Raise the TranzPak2 module to the slot.
and insert into the docking bay .
2. Use your finger to gently push on the
TranzPak2 finger plate until the module
is seated against the rear connector.
3. Press the locking handle until it snaps
into place.
INSERTING THE TRANZPAK2 MODULE
OPERATIONS
STATUS INDICATOR
The Z X1 features status lights to ef fectively monitor the activities of the product. :
OPERATIONS
Power On LED
1.
Orange = 5V standby available, system
is in standby (meaning OFF) mode.
2. Green = system is ON.
3.
OFF = system is not connected to an
AC power source
OT (Over Temp) LED
1. OFF = System temperature is normal
2.
Blinking Red Light = This is a warning
that the system temperature is getting
close to operational limits.
3.
Solid Red Light = System is at its
operational limit. User intervention is
needed.
LAN LED 1 and 2
1. Blinking green = LAN port is connected
and functioning normally
2. OFF = LAN port is not connected
and/or disabled
HD LEDs
1. OFF = No hard drive activity or no
hard drive connected
2. Blinking orange = Indicates hard drive
activity
Fan LED – (LED with “Fan” text and
fan symbol)
1.
Green = system fans are running
normally
2.
Orange = one or more system fans is
malfunctioning
3.
RED = all system fans are
malfunctioning or system fans are not
installed
Содержание ZX1