background image

               

Z-Light 6TX/16TX/26TX Intelligent Direct Modulated Optical Transmitter   

 

www.z-band.com

 

    All Rights Reserved © 2018 Z-Band Technologies, LLC. 

Phone: (866) 902-2606 

 

- 2 - 

FAX: (717) 249-3253 

 
 

 

Provide the Required Power sources:

    Operate this equipment only from the type of 

power source indicated on the rear panel.    CAUTION: For continued protection against 

risk of fire, replace the fuses (if necessary) with only one of the same type and rating. 

 

Adequate Grounding and Power Polarization:

    This equipment is equipped with 

polarized AC line plugs (a plug having one blade wider than the other). This plug will fit 

into the power outlet only one way as a safety feature. Do not defeat the safety purpose 

of the polarized plug.   

 

INSTALLER NOTE:

    This reminder is provided to call your attention to guidelines for 

proper grounding.    Specifically the cable ground shall be connected to the building 

grounding system, as close to the point of cable entry as practical.    The equipment 

enclosure ground must also be attached and a ground screw connection is provided on 

the rear of the equipment enclosure for this purpose. 

 

Servicing:

    Refer all servicing to qualified personnel. Opening or removing covers may 

expose dangerous voltages.    THESE TRANSMITTERS DO NOT HAVE USER 

SERVICABLE INTERNAL PARTS 

– DO NOT OPEN THE TRANSMITTER CABINET.   

When replacement parts are required (the replaceable power supplies), make sure the 

service technician uses only replacement parts provided by Z-Band Technologies, LLC. 

(available from Z-Band Technologies-Authorized Distributors) and to SERVICE ONLY 

WHEN POWER HAS BEEN DISCONNECTED. Unauthorized substitutions may result in 

fire, electric shock, or improper operation of the unit and void all warranties. 

 

Optical Output Safety:    1310nm and 1550nm Optical Transmitter units may emit 

harmful invisible laser radiation. These products may emit harmful laser radiation 

if powered on and the case is opened or 

the optical path is exposed. DANGER:    DO 

NOT WORK ON THE OPTICAL PATH, 

CONNECTIONS, ETC WHEN 

TRANSMITTER POWER IS ON. 

 

Laser Safety Information: 

 

Viewing the laser output with (or even without instruments) may pose an eye hazard. 

 

Laser power could be accessible if optical connector is open or fiber is broken. 

 

CAUTION:    Lasers may be on whenever the transmitter is powered. 

 

CAUTION:    Use of controls, adjustments, and procedures other than those 

specified herein may result in hazardous laser radiation exposure. 

 

DANGER:

    1310nm and 1550nm Optical Transmitter units may emit harmful 

invisible laser radiation. These products may emit harmful laser radiation if 

powered on and the optical path is exposed or the case is opened. DANGER:    DO 

Содержание Z-Light 6TX

Страница 1: ...al is intended solely for use by purchasers of Z Band Technologies LLC transmitters and their qualified service technicians This document is the property of Z Band Technologies LLC and incorporates pr...

Страница 2: ...bodily harm do not expose this equipment to rain or moisture and DO NOT OPEN THIS EQUIPMENT Optical Output Safety 1310nm and 1550nm Optical Transmitter units may emit harmful invisible laser radiatio...

Страница 3: ...NSMITTERS DO NOT HAVE USER SERVICABLE INTERNAL PARTS DO NOT OPEN THE TRANSMITTER CABINET When replacement parts are required the replaceable power supplies make sure the service technician uses only r...

Страница 4: ...Panel 9 3 3 Power Module 9 3 3 1 110 240VAC Power Module 9 3 4 Menu Operation 10 3 4 1 Main Menu 10 10 3 4 2 Display Parameters Menu 11 3 4 3 Set Parameters Menu 13 3 4 4 Alarm Status Menu 14 4 Insta...

Страница 5: ...leshooting 29 6 3 After Sales Service 31 6 4 Disclaimer 31 Safety Reminder DANGER The transmitter emits invisible laser radiation AVOID DIRECT EXPOSURE TO LASER Never operate the unit with a broken fi...

Страница 6: ...u the communication settings of the Z Light 6TX 16TX 26TX Chapter 6 describes maintenance and what to do in the event of problems 1 2 Product Description The Z Light 6TX 16TX 26TX intelligent directly...

Страница 7: ...ORTEL DFB Laser Dual redundant hot swappable power supply modules 48VDC optional Use in 1310nm Optical fiber transmission systems Building CATV HFC networks 2 Technical Parameters Item Unit Technical...

Страница 8: ...e humidity Max 95 no condensation Dimension mm 483 W 380 D 44 H 19in W x 15in D x 1 75in H Optical link carrier to noise ratio degradation table Optical power Optical link loss dB 4 5 6 7 8 9 10 11 12...

Страница 9: ...Power on LED Green Status Indicator RUN Running normally LED Flashing Green Laser Status Indicator ON OFF Laser OFF LED Flashing Red Laser ON LED Green RF Input Indicator RF No input or exceeds the no...

Страница 10: ...a Input ports are both interchangeable as RF inputs 4 5 RF Data Test RF input Test ports 20dB compared to RF Data input ports 11 Ground Screw Used for connecting the transmitter to building ground 6 O...

Страница 11: ...0nm Direct Modulated Optical Transmitter with a 6mW output After the unit passes self test rotate the key to the ON position which will then be shown on the display The main menus are only accessible...

Страница 12: ...meters Enter Laser Output xx x dBm Laser Bias xx x mA Laser Temp xx x Tec Cooling Amp x xx A RF Chan NO 10 ESC IP Address xxx xxx xxx xxx Subnet Mask xxx xxx xxx xxx Net Gateway xxx xxx xxx xxx Mac XX...

Страница 13: ...being transmitted setting this in the SET PARAMETERS menu gives better accuracy in the RF signal levels displayed Laser RF Laser RF input signal level RF Control Mode RF control mode either AGC or MGC...

Страница 14: ...e 866 902 2606 13 FAX 717 249 3253 3 4 3 Set Parameters Menu 2 Set Parameters Enter Set Buzzer Alarm Set RF Control Mode Set MGC ATT Set AGC Ref Set IP Address ESC ON OFF AGC MGC 0 dB X dBm Set SubNet...

Страница 15: ...Mode Set the RF control mode Either AGC or MGC Set MGC Att Set the ATT in MGC mode Attenuation adjustable range 0 20dB Set AGC Ref Set the offset in AGC mode Adjustable range 5dB Set Local IP Address...

Страница 16: ...ht carrier and Z Band Technologies LLC 4 1 1 Instruments and tools 1 An optical power meter 2 A digital multimeter 3 A standard optical fiber test jumper SC APC for standard SC APC 4 Fiberoptic cleani...

Страница 17: ...omplies with the requirements and the power supply switches are in the OFF position Then connect the power supplies AC power cords 4 Attach the coaxial cable and input the RF signal turn the power sup...

Страница 18: ...tton is trapped tap the button to move it so that it is able to move freely 4 3 2 Connecting the RF Cables Connect the RF input cable to the rear of the Transmitter A 20dB RF test connector is located...

Страница 19: ...the transmitter s RJ 45 Ethernet port The Ethernet port is on the rear panel of the transmitter 2 Verify that the green Link LED is illuminated indicating that there is a connection 4 3 5 Connecting P...

Страница 20: ...3 RX 4 No Connect 5 GND 6 No Connect 7 No Connect 8 No Connect 9 No Connect The serial communication uses the standard NRZ form 1 start bit 8 data bits 1 stop bit and the baud rate is 38400 5 2 Setti...

Страница 21: ...Sessions name such as Z Band TX and choose the Serial line the computer serial or USB adapter port your serial cable is installed on your computer to connect with your transmitter Select Serial in the...

Страница 22: ...start a PuTTY session 5 3 Operating Parameters Configuration With the transmitter power off use the serial port cable to connect the RS232 port with the computer port Open PuTTY which you have already...

Страница 23: ...the following commands help ethcfg settrap community Restore setpswd Exit Specific command use is as follows help This command shows current application program version program name and the internal...

Страница 24: ...mmand shows or modifies the host IP address list of the SNMP Trap IP addresses of 0 0 0 0 and 255 255 255 255 don t exist SNMP Trap does not send to these two addresses community This command configur...

Страница 25: ...l SNMP is an application layer protocol It makes the management information and control between network devices much easier It is part of the TCP IP protocol SNMP enables the end users to manage netwo...

Страница 26: ...the IE browser and entering the transmitter IP address displays the following transmitter login page You can read the IP address from the transmitter s Disp Parameters LCD menu OR set it to a new IP a...

Страница 27: ...ng interface above at any time This interface displays the device parameters including optical output power laser bias current optical wavelength and power supply voltage etc Click Set Parameter to op...

Страница 28: ...r Z Band Technologies LLC warranty Dirty optical connectors lead to optical signal loss and reflections which in turn can seriously degrade signal to noise SNR performance and in some cases distortion...

Страница 29: ...nate the connectors and fiber 6 1 1 Cleaning Patch Cord or Pigtail Fiber Optical Connectors CAUTION LASER Remove power before working on the optical connections Observe all safety precautions To clean...

Страница 30: ...re both normal but the actual measured optical output power is low 1 The poor quality of the test jumper 2 The active fiber connector or adapter may be contaminated 3 The ceramic tube in the adapter m...

Страница 31: ...mode 3 Use a spectrum analyzer to check the system link C N and make appropriate adjustments Make sure the system link signal C N 51dB After initial startup the video image has randomly appearing noi...

Страница 32: ...y damaged adapter 6 3 After Sales Service 1 When the equipment malfunctions immediately contact your local in country dealer or distributor or directly call our Z Band Technologies LLC USA Technical S...

Отзывы: