Venting Pressure Gas
Figure 229
Refer to the Venting Pressure Gas Operational Sche-
matic figure 229, on page 77.
1. Open valve V3
CA
CA
CA
CA
CAUTION:
UTION:
UTION:
UTION:
UTION:
Vented gas will have a strong odorant smell.
2. Connect a Gas Flare Device or Odorant Filter /
Scrubber as required, to the Expansion Tank Vent
connection on the back of the NJEX System
enclosure
3. Slowly open valve V5 and allow all pressure to vent
from the NJEX System