3. Adjust the pump volume adjustment knob to
the value used in the calculations in step 1.
4. Turn mode switch 1 to on.
5. Turn mode switch 2 to on.
6. Turn mode switch 3 to off.
7. Turn mode switch 4 to off.
8. Press the test button once to initiate the
timer sequence.
Number of turns open on the pump volume knob
3
6
12
Sample pump displacement per stroke
.1cc
.2cc
.4cc
System
Mutual
Approved
Factory
IMPOR
IMPOR
IMPOR
IMPOR
IMPORTTTTTANT NO
ANT NO
ANT NO
ANT NO
ANT NOTE:
TE:
TE:
TE:
TE:
For the Z-65 to operate the DP-2010 System, a
minimum pressure differential of 3" of water
must exist between the high pressure and low
pressure ports of the DPS-2.