12.4 Timer Range Setting
A. There are two Z-65 models: the Z-65/6.1 and
Z-65/6.03. Each Z-65 timer has two ranges for the
timer setting dials.
1. Z-65/6.1 Range Setting:
a. xx minutes: set the configuration jumper to the
far left position (factory setting).
b. x.x minutes: set the configuration jumper to the
center position.
2. Z-65/6.03 Range Setting:
a. x.x minutes: set the configuration jumper to the
far left position (factory setting).
b. .xx minutes: set the configuration jumper to the
center position.
Note: To obtain maximum battery life, choose the
longest solenoid stroke rate possible.
factory positioned
for 1 - 99 counts (xx)
Jumper switch location
Jumper switch location
for .1 - 9.9 counts (x.x)
Mutual
System
Approved
Factory
Mutual
System
Approved
Factory
12. Troubleshooting
Timer Mode