Important notes

Maintenance

Please  store  the  monitor  and  accessories 
properly after use.
Do not place the monitor and accessories in 
high temperature, moisture, dust, or exposure 
to sunshine.
The cuff contains an airbag inside, please care in 
applications, do not fold, pull or twist it.
Do not modify the device without authorization.
Do not replace the parts without authorization.
Please clean the monitor with soft dry cloth. If 
it's necessary, please use wiped soft cloth with 
water or 

before cleaning by soft 

dry cloth.
Using absorbent cotton to wipe gently with rubbing 
alcohol,  disinfection of  the  machine  when  it 
necessary. Do not use detergent to clean.
Do not let water seep into the device.

75% alcohol

 

Please observe the following items to protect 
the  device  and  ensure  the  accuracy  of 
measurement.

We suggest to calibrate the monitor (at 

 

least

once a year) according to local laws and 
regulations. Please 

contact the manufacturer  

 

or agent if need.

Tips!

Please disconnect the plug of adapter with 
mains  when  you  need  to  safely  terminate 
operation of ME EQUIPMENT.
When it is dirty in single patient daily use, 
clean the monitor with soft dry cloth. If it is 
necessary, please use wiped soft cloth with 
water before cleaning by soft cloth. Then clean 
the device with 75% alcohol.
When multiple patients use between uses on 
different patients, cleaning with 75% alcohol 
must be conducted after each use.
Do not let the alcohol flow into the monitor 
and arm cuff.

Note: Do not diagnose with the measurement, 
Please follow doctor's instruction. 
Statement: If the monitor has not been stored 
in  the  required  temperature  and  humidity 
range, it may not conformance to specification.

Содержание YE680B

Страница 1: ...ng Jiangsu Province P R China 210000 Manufacturing Address YunYang Industrial Park DanYang Jiangsu Province P R China 212300 http www yuwell com Please read the user s manual closely before using YE68...

Страница 2: ...Auxiliary measuring function Static mode Common problems Common questions of blood Pressure measurement Common fault and trouble shooting Technical parameters Health diary Electromagnetic compatibilit...

Страница 3: ...cover Power on Operation guide 1 Using method of cuff Wearing the cuff and make the lower edge 2 3cm above the elbow keep the air tube inside of the arm Please turn to page 19 for details 2 3cm Measur...

Страница 4: ...s the button of check the measuring records This monitor can display the average measurement and store 99 records Please turn to page 24 for details 1 Main part Display Member button Memory button Sta...

Страница 5: ...A MFR JIANGSU CHENYANG ELECTRON CO LTD US Model CYSM06 060060 UL C EU Model CYSM06 060060 CE C 4 User s manual Warranty card 4xAA batteries SYS systolic Pulse rate Low voltage Blood pressure level dis...

Страница 6: ...pulse rate of adult at household or medical center not suitable for neonate pregnancy or pre eclampsia Pay attention to the following points when measuring or it may cause the incorrect results Sit s...

Страница 7: ...he CUFF over a wound arm or being on an intravenous drip Consult your doctor if using the device on the arm with an arterio venous A V shunt Do not use the cuff on the arm where the side of a mastecto...

Страница 8: ...ing items to protect the device and ensure the accuracy of measurement We suggest to calibrate the monitor at least once a year according to local laws and regulations Please contact the manufacturer...

Страница 9: ...r setting Press the button and for more than 3 seconds till the number starts flashing 2 The year increase once press the button 3 Press the button to switch to the month setting 4 Using the same way...

Страница 10: ...unit setting Press the button to switch between these two pressure units Finish by pressing the button After finishing the volume setting pressing After unit setting press the button to shut down Pres...

Страница 11: ...enter of cuff and heart at the same level Also please ensure the air tube not twisted Using method of cuff Wind the cuff around the upper arm as shown Stick the cuff tightly Note The cuff should be we...

Страница 12: ...en table and chair is 25 30cm back and arm being supported Sit on a chair with your feet flat on the floor Don t eat smoke drink take bath or do any high impact sport within half an hour before measur...

Страница 13: ...pressure release value starts to decrease gradually 2 Measurement finished After measurement the monitor will show the SYS DIA and pulse rate then inflate the air automatically m MEMBER SYS mmHg DIA m...

Страница 14: ...terval between two measurements should be at least 5 minutes or longer Estimate the blood pressure condition according to the BP classification table and consult the doctor Blood pressure range indica...

Страница 15: ...e measurement need stoping for uncomfortableness or other reasons please press the button the measurement will stop immediately and air releases fast Take off the cuff manually if the button is not wo...

Страница 16: ...ed data by pressing the button as the sequence 1 2 99 max D Press the button to shut off the monitor 2 Delete the recorded data If the cuff winded properly it will show the icon Otherwise it will show...

Страница 17: ...press the button to stop inflating and take out the batteries to enter the next step System restores Static mode Press the button and hold meanwhile install the batteries Hold on for about 3 seconds...

Страница 18: ...2 33 kPa mmHg k a mmHg P 12 0 18 5kPa 90 139mmHg 18 7 21 2kPa 140 159mmHf 12 0 13 2kPa 90 99mmHg 21 3 23 9kPa 160 179mmHg 13 3 14 5kPa 100 109mmHg 24 0kPa 180mmHg 14 7kPa 110mmHg 8 0 11 9kPa 60 89mmHg...

Страница 19: ...In hypertensive individuals variations are even more pronounced Normally the blood pressure rises while at work or play and falls to its lowest levels during sleep So do not be overly concerned by the...

Страница 20: ...The icon twinkle 36 37 300mmHg...

Страница 21: ...sification Service life Weight Dimension Operating temperature Humidity Storage temper ature Humidity Operating Storage atmospheric pressure 70kPa to 106kPa There is the potentia risk of radio frequen...

Страница 22: ...nment YE680B Immunity test IEC 60601 test level Compliance level Electrostatic discharge ESD IEC 61000 4 2 Electrical fasttransient burst IEC 61000 4 4 2 kV 100kHz repetition frequency Surge IEC 61000...

Страница 23: ...relocating the YE680B b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Radiated RF IEC 61000 4 3 10 V m 80 MHz to 2 7 GHz 3 Vrms 0 15 MHz 80 MHz 6 V rms in ISM an...

Страница 24: ...44 45 Health diary Health diary...

Отзывы: