Yuwell YE660E Скачать руководство пользователя страница 14

24

25

If  the  SYS  is  higher  than  139mmHg  or  DIA 
higher than 89mmHg means having high blood 
pressure. Please contact with doctor for advice.
Also  the  Blood  pressure  range  indicator  can 
show the blood pressure intuitively.

Tips!

The time interval between two measurements 
should be at least 5 minutes or longer.
Estimate  the  blood  pressure  condition 
according  to  the  BP  classification  table,  and 
consult the doctor.

Blood pressure range indicator

Start measuring

4

Shut down

Press the"             "button to shut down. Also it 

will power off automatically in 3 mins without 

any operation.

3. T

ake off the cuff

Higher than 139mmHg

Higher than 89mmHg

  SYS

mmHg

  DIA

mmHg

P/min

AM

YE660 (

)

尺寸:180X142.5mm           色彩:准确、单色,层次分明

纸张:80克双胶纸                印后加工:对折装订 

E CE认证 电子血压计说明书印刷要求

 

 

Содержание YE660E

Страница 1: ...ng Jiangsu Province P R China 210000 Manufacturing Address YunYang Industrial Park DanYang Jiangsu Province P R China 212300 http www yuwell com Please read the user s manual closely before using YE66...

Страница 2: ...eatures Operation guide Parts Important notes Maintenance Battery installation Time and date setting setting Measuring method Using method of cuff Measuring posture Start measuring Blood pressure rang...

Страница 3: ...ower edge 2 3cm above the elbow keep the air tube inside of the arm Please turn to page 19 for details 2 3cm Measurement 2 Measuring posture Sit straightly keep the center of cuff and heart at the sam...

Страница 4: ...easuring records This monitor can display the average measurement and store 99 records Please turn to page 24 for details Power adapter socket Battery cover Plug port SYS mmHg DIA mmHg P min Display M...

Страница 5: ...Model CYSM06 060060 UL C EU Model CYSM06 060060 CE C 4 User s manual Warranty card 4xAA batteries SYS systolic Pulse rate Low voltage Blood pressure level display Cuff Detection Wrapping Deflation Inf...

Страница 6: ...at extreme temperature condition or the varied severely environment Do not take the measurement in a moving vehicle Pay attention with the symbols shown here to prevent harm or damage to the user sign...

Страница 7: ...ttery might result in measurement error Please follow the battery requirement of manufacturer To report unexpected operation or events Do not measure continuously 5 minutes or more should be spared be...

Страница 8: ...ing items to protect the device and ensure the accuracy of measurement We suggest to calibrate the monitor at least once a year according to local laws and regulations Please contact the manufacturer...

Страница 9: ...upplied by us Please take out the batteries if use the DC external power for a long time more than one month Time and date setting 15 14 Battery installation Open the battery cover Install the batteri...

Страница 10: ...nit setting Press the button to switch between these two pressure units Finish by pressing the button After finishing the volume setting pressing After unit setting press the button to shut down Press...

Страница 11: ...the center of cuff and heart at the same level Also please ensure the air tube not twisted Using method of cuff Wind the cuff around the upper arm as shown Stick the cuff tightly Note The cuff should...

Страница 12: ...ween table and chair is 25 30cm back and arm being supported Sit on a chair with your feet flat on the floor Don t eat smoke drink take bath or do any high impact sport within an hour before measuring...

Страница 13: ...licker pressure release value starts to decrease gradually Full screen display state 2 Measurement finished After measurement the monitor will show the SYS DIA and pulse rate then deflate the air auto...

Страница 14: ...time interval between two measurements should be at least 5 minutes or longer Estimate the blood pressure condition according to the BP classification table and consult the doctor Blood pressure rang...

Страница 15: ...he measurement need stoping for uncomfortableness or other reasons please press the button the measurement will stop immediately and air releases fast Take off the cuff manually if the button is not w...

Страница 16: ...ed data by pressing the button as the sequence 1 2 99 max D Press the button to shut off the monitor 2 Delete the recorded data If the cuff winded properly it will show the icon Otherwise it will show...

Страница 17: ...press the button to stop inflating and take out the batteries to enter the next step System restores Static mode Press the button and hold meanwhile install the batteries Hold on for about 3 seconds...

Страница 18: ...2 33 kPa mmHg k a mmHg P 12 0 18 5kPa 90 139mmHg 18 7 21 2kPa 140 159mmHf 12 0 13 2kPa 90 99mmHg 21 3 23 9kPa 160 179mmHg 13 3 14 5kPa 100 109mmHg 24 0kPa 180mmHg 14 7kPa 110mmHg 8 0 11 9kPa 60 89mmHg...

Страница 19: ...ormally the blood pressure rises while at work or play and falls to its lowest levels during sleep So do not be overly concerned by the results of one measurement Take measurements at the same time ev...

Страница 20: ...The icon twinkle 36 37 300mmHg...

Страница 21: ...ication Service life Weight Dimension Operating temperature Humidity Storage temper ature Humidity Operating Storage atmospheric pressure 70kPa to 106kPa There is the potentia risk of radio frequency...

Страница 22: ...ow The customer or the user of the YE680B should assure that it is used in such and environment YE680B Immunity test IEC 60601 test level Compliance level Electrostatic discharge ESD IEC 61000 4 2 Ele...

Страница 23: ...easures may be necessary such as reorienting or relocating the YE660E b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Radiated RF IEC 61000 4 3 10 V m 80 MHz to...

Страница 24: ...Health diary 44 45 Health diary...

Отзывы: