Charging Pile Instructions-V2.0
40
33
Cabinet
temperature
signal
abnormal alarm
Check if the ambient temperature
is too high
36
Cabinet
temperature
signal
abnormal protection
Check if the ambient temperature
is too high
42/43
Parallel contactor 1/2 feedback
signal abnormal
Check parallel contactor 1/2
feedback signal line
50~53
Control
board
1~4
CAN
communication timeout
Check control board 1~4 CAN
communication line
60~67
Parallel contactor 3~10 feedback
signal abnormal
Check parallel contactor 3~10
feedback signal
70
Power
control
board
communication timeout
Check the communication line of
the power control board
71~74
Communication timeout between
vehicle connector 1~4 and power
control board
Check the communication line of
vehicle connector 1~4 and power
supply board
80~140
Switch
board
1~60
communication timeout
Check the communication line of
the switch board and power
supply board in the power cabinet
141~200
Switch board 1~60 contactor
adhesion
Check whether the relay of the
switch board adhesive
Vehicle Connector Fault classification number: 11 (Connector 1) ~ 18 (Connector 8)
Such fault happens only in charging process. Treatment of stop charging pile or ignore the
faults need to be chose according to fault severity. The faults could be cleared in standby
state.
Fault code
Fault name
Treatment method
2
Meter communication fault
Check the meter
3
Meter
displayed
value
not
accurate
Check the meter
4
Output over current
Check if the actual current is too
large
5
Insufficient IC card balance
Recharge IC card
6
Wrong virtual card charging
request
7
Blacklist card