JANUARY 1997 (revised Sept 2008) 

 

INSTALLATION INSTRUCTIONS MULTI FUEL 

ZERO CLEARANCE* INBUILT 

 

COMPLIES WITH NZS 7421-1990, AND NMZ 7421-1985 CLAUSE 307-3 

 

*The  original  testing  was  designed  to  cater  for  older  homes  with  brick  or  pumice  cement 
chimneys that incorporated brick open fires and had contact on the outer surfaces with timber 
framing  and/or  cladding.  This  also  included  for  timber  contact  above  the  fire  opening  lintel. 
The term zero clearance as used with the old standard, NZS 7421:1990 Appendix J, referred 
in  the  main  to  the  "zero"  clearance  contact  with  the  outer timber  framing  /  cladding  with  the 
outer surfaces of the brick fireplace cavity and chimney. This same set of conditions does not 
apply to how zero clearance is used in today’s language, where inbuilt fires are installed into 
internal timber framed fireplace enclosures 

 

A.  The  manufacturer  recommends  all  installations  be  carried  out  by  competent  trades 

persons  (e.g.  space  heater  installer)  to  obtain  maximum  performance  and  maintenance 
free heating. 

 
B.  A permit is required and we suggest you check with your local building inspectors as by-

laws vary from area to area. Also notify your insurance company that a space heater has 
been installed. 

 

C. 

Hearth

 –   1.  Must extend at least 300mm in front of the heater glass. 

 

2.  Must extend at least 150mm either side of the heater 

 

3.  Must  be  constructed  of  non-combustible  materials  giving  heat  resistance 

equal to concrete or brick at least 50mm thick. 

 
D. 

Mantel

 -  A minimum of 600mm is required from the top of the fascia panel to any heat 

sensitive material. 

 
E. 

Flue Kit

 –  3.6m of 150mm dia stainless steel flue. 

1 x weather cap and cowl 
1 x steel deflector shield. 
 

F.  

NOTE

 -  

1.  All joints must be sealed with flue sealing compound and screwed or riveted 

together. 

2. 

IMPORTANT

:  Pack  Kao  wool  or  similar  around  the  firebox  outer  case  and 

wire in place. Place kao wool (or similar) over the top of the firebox. (ref pg 2) 

3. Seal between fascia and fireplace. (ref page 2) 
 

G. 

Waterbooster

  (Wetback).  Holes  may  be  pre-drilled  in  the  rear  of  the  fire  box  ready  to 

knock out however these are not suitable for inbuilt installations (side entry may 
be better suited). The installer may drill at a C/L height of 352mm for the cold-in 
pipe, and at 422mm for the hot-out pipe. 

 

This appliance is not clean air approved. 

Additional copies of installation instructions and operations/maintenance information 

can downloaded from our website 

www.yunca.co.nz

 