2.2 Parameter settings
Press and hold the POWER and MODE buttons at the same time to access the settings. in exchange for configuration. Press
MODE to advance (1) or press POWER to decrease. Desired configuration will be set after about 3 seconds.
Note: Keep the default values of the parameter settings, please do not change them at will. (p9 is an electronic brake, can be
adjusted, or is not electronic
Press MODE to go to the next setting from PO
PO
P1
P2
P3
P4
P5
Wheel diameter in inches. Default = 10
Voltage cut. Default = 38
Magnetic poles in the hub motor. Default = 10
Speed sensor function. Default = 0
0 # Km / h, 1 # Mh. (speedometer in kilometer or mile)
0 = Start without kick 1 = Start with kick
P6
0 = No cruise 1 = Cruise
P7
0 = Start of power 1 = Normal start
P8
Power setting, from 0 to 100, 100 means total power
P9
Electronic value of the braking force. Default = 2
P10 Function to be determined.
09
2.3 Fault screen
When theelectric vehicle fails, theinstrumentshows defectivecomponents, suchasenginefailure (
), controller failure
(
), controller failure (
), and so on.
2.4 Function Screen
Some meter functions will show symbols, respectively, headlights on (
) USB charging (
).
2.5 Wiring harness definition
Red: VCC
Orange: electric lock
Black: earth
Green: Hall signal
Blue: signal transmission
Yellow: signal reception