*1.  For NULL adjustment, remove the protective screw and turn the trimmer behind the screw. 

After adjustment, be sure to attach the protective screw. 

*2.  The 6 + PE connector is not included with the valve.    Prepare it separately. 

YUKEN parts number: TK290457-1 

*3.  With standard sub-plates, one (“T

A

”) of the two tank ports is used, but either one may be used. 

 
 
 

 Dimensions of Mounting Surface 

Prepare the mounting surface as shown below.  Basically, the dimensions of the mounting 
surface conform to ISO 4401-05-04-0-94.  The mounting surface should have a good 
machined finish, e.g. surface roughness of 6-S. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Indicator Lamp 

Cylinder Port “A”  Pressure Port “P“ Cylinder Port “B“ 

M5 (+) Thd.

Tank Port “T

A

7 Dia. Through

Air Vent 
3 Hex. Soc. 

Indicator Lamp

Color 

Green

Red 

Power Supply

Deviation Alarm

Cable Applicable:
Outside Dia. 8 - 10 mm 

6 + PE Connector

*2

Nameplate

Mounting Surface 
(O-Rings Furnished) 

 

Protective Screw for NULL Adjuster Hole

*1

 

Tank Port “T

B

4 Places 

11 Dia. 

4 Places 

M6 Thd. 13 Deep 

 O-Rings for the Ports 

AS568-014 (NBR, Hs90): 5 Pieces

11 C’ Bore 4 Places

Содержание ELDFG EH 3C2-XY-C Series

Страница 1: ...read this manual thoroughly before use Be sure to follow the instructions described in the Safety Precautions section of this manual Keep this manual at hand for future reference When creating instru...

Страница 2: ...made to the product Although this manual has been prepared with great care please contact the place of purchase or our customer support if you find any ambiguous explanations errors or omissions If t...

Страница 3: ...ng the main body of this manual Symbols and definitions for safety precautions in this manual are as follows Symbols and definitions for safety precautions in this manual are as follows Ignoring safet...

Страница 4: ...he instructions for the connector For the use of YUKEN s connector TK290457 1 see the Wiring section of this manual Never touch the connector while the power is on Doing so may cause electric shock re...

Страница 5: ...e dimensions 11 3 2 Required tools 11 3 3 Check of the valve mounting surface 11 3 4 Mounting position 11 3 5 Installation 12 4 Wiring 4 1 Recommended cable 13 4 2 Connection between the cable and the...

Страница 6: ...type 3C2L is suitable for position control 2 overlap 1 3 Product check Check the following points upon delivery of the product If any questions or problems arise please contact the place of purchase...

Страница 7: ...lectric Connection 6 PE Connector 1 Use the valves so that the relationship between the valve pressure difference and the flow rate as specified in Range of flow control on page 7 is met 2 This value...

Страница 8: ...nge of flow control Control Method 4 Way Valve Control Method 3 Way Valve Valve Pres Diff MPa Valve Pres Diff MPa Valve Pres Diff MPa Valve Pres Diff MPa Flow Rate L min Flow Rate L min Flow Rate L mi...

Страница 9: ...n below Basically the dimensions of the mounting surface conform to ISO 4401 03 02 0 94 The mounting surface should have a good machined finish e g surface roughness of 6 S Indicator Lamp Cylinder Por...

Страница 10: ...ace as shown below Basically the dimensions of the mounting surface conform to ISO 4401 05 04 0 94 The mounting surface should have a good machined finish e g surface roughness of 6 S Indicator Lamp C...

Страница 11: ...e recommended load resistance is 200 Fail Safe Function 1 Model Number Spool Position Function Graphic Symbols F ELDFG EH 3C2 XY C Neutral All Ports Blocked F ELDFG EH 3C2L XY C Neutral or or F ELDFG...

Страница 12: ...Number Tool Name Use ELDFG 01EH Hexagon Wrench Width Across Flats 4 mm For M5 Valve Mounting Bolts ELDFG 03EH Hexagon Wrench Width Across Flats 5 mm For M6 Valve Mounting Bolts ELDFG EH Phillips Screw...

Страница 13: ...FG 03EH M6 35L 13 16 Nm For valve installation use the specified number of bolts and apply the specified tightening torque Failure to do so may cause damage to the bolts or outflow of hydraulic fluid...

Страница 14: ...yvinyl chloride insulated flexible cords for microphone shielded MVVS or the equivalent JIS C 3306 Polyvinyl chloride insulated flexible cords shielded VCTF or the equivalent JIS C 3401 Control cables...

Страница 15: ...lead wire size is 1 0 mm2 AWG17 or less c Terminate the end of the cable as shown below Peel off the length of the cable sheath and the ends of the lead wires as shown above 2 Wiring a Pass the cable...

Страница 16: ...stment range is about 15 Indicator Lamp Power Supply Green Lights up when the valve is powered on Deviation Alarm Red Lights up when the spool travel deviates about 3 or more from the input value and...

Страница 17: ...t noise such as inserting a noise filter on the power supply side Do not share the AC power source to the DC power supply with high noise generating equipment solenoid operated directional valves heat...

Страница 18: ...the following items 1 When the power indicator LED green does not light up Check the power supply voltage Check the power supply side if no voltage is present 2 When the deviation alarm LED red light...

Страница 19: ...lic fluid resulting in unstable valve operation and or solenoid failure Do not connect the tank port to any line that generates a surge pressure Doing so may cause malfunction or failure of the valve...