Yuasa SmartShot 900 Automatic 12V 900mA Скачать руководство пользователя страница 38

Dry Charged 

Battery plates that

have been subjected to the dry charg-

ing process.

Dry Charging

Manufacturing

process in which tank-formed battery

plates are washed free of acid and

then dried.

Efficiency 

The ratio of  the output of

a cell or battery to the input required

to restore the initial state of charge

under specified conditions of tempera-

ture, current rate and final voltage.

Electrode

A conductor through

which current passes in or out of a cell.

Electrode  (Electrolyte) Potential

The difference in potential between the

electrode and the immediately adja-

cent electrolyte, expressed in terms of

some standard electrode potential dif-

ference.

Electrolysis

Electrochemical reac-

tion that causes the decomposition of a

compound.

Electrolyte 

Any substance that dis-

associates into two or more ions when

dissolved in water.   Solutions of elec-

trolyte conduct electricity and are

decomposed by it.  For batteries, elec-

trolyte implies a dilute solution of sulfu-

ric acid.

Electromotive Force (EMF)

Electrical pressure or potential,

expressed in volts.

Element

An assembly of a positive

plate group, negative plate group and

separators.

End Gravity

The specific gravity of

a cell at the end of a prescribed dis-

charge.

Energy Density 

Ratio of  battery

energy content in watt hours to battery

weight in volume.

Envelope

A separator folded and

wrapped around a battery plate dur-

ing assembly.    

Equalizing Charge

An extended

charge given to a storage battery to

ensure complete restoration of active

materials in all the plates of the cells.

Expander

An ingredient in the neg-

ative paste that delays shrinking and

solidifying of the sponge lead of the

finished plate, thereby enhancing neg-

ative plate capacity.

Ferroresonant Charger  

A con-

stant volt power supply containing a

special transformer-capacitor combi-

nation that changes operating charac-

teristics as the draw is varied, ensuring

that voltage output remains constant

.

Filling Gravity  

The specific gravity

of acid used to fill batteries. 

Final Voltage

The cut-off voltage of

a battery.  The prescribed voltage

reached when the discharge is consid-

ered complete.

Finishing Rate 

The rate of charge,

in amperes, to which charging current

is reduced near the end of the charge

for some types of batteries to prevent

gassing and temperature rise.

Fixed Resistance Discharge

Discharge of a cell or battery through

a fixed resistive load, the current being

allowed to fall off as the terminal volt-

age decreases.

Float Plate

A  pasted plate.  

Float Charging

A recharge at a

very low rate, accomplished by con-

nection to a buss whose voltage is

slightly higher than the open circuit

voltage of the battery.

Foot

Projections from the grid at the

bottom edge, used to support the plate

group.

Formation or Forming Charge

An initial charging process that elec-

trochemically converts the raw paste of

the plates into charged active material,

lead peroxide in the positive plates

and sponge lead in the negative

plates.

Formed

Plates that have undergone

formation.

Freshening Charge

A charge

given batteries in storage to replace

the standing loss and ensure that every

plate is periodically brought up to full

charge.

Full Charge Gravity

Specific

gravity of the electrolyte when cells are

fully charged and properly leveled.

Gang Vent

Vents for usually six

adjacent cells that are connected to a

common manifold.

Gassing

Bubbles from gases being

released at one or more of the elec-

trodes during electrolysis. 

Glass Mat 

Fabric made from glass

fibers with a polymeric binder such as

styrene or acrylic which is used to help

retain positive active material.

Gravity

Specific gravity.

Gravity Drop

The number of points

reduction or drop of specific gravity of

the electrolyte from cell discharge.

Grid

A metallic framework used in a

battery for conducting electric current

and supporting the active material.

Group

One or more plates of one

type – positive or negative – burned to

a post or strap.

H

2

SO

4

Sulfuric Acid.

High Rate

On charge, any rate

higher than the normal finishing rate.

Hydration (Lead)

Reaction

between water and lead or lead com-

pounds.   Gravities lower than those

found in discharged cells are apt to

produce hydration, which appears as

a white coating on plate groups and

separators in a cell.

36

GLOSSARY

Содержание SmartShot 900 Automatic 12V 900mA

Страница 1: ......

Страница 2: ...sa s Automatic 900mA 12V battery charger is the industry s most powerful plug in wall charger Combining the latest technology and a host of user friendly features this compact high power unit provides...

Страница 3: ...s 16 Inspecting a Battery 16 17 Battery Testing Devices 17 Battery Testing 18 Chargers and Charging 19 20 Charging a New Standard Battery 20 21 Quick Charges 21 SECTION FOUR Maintenance and Storage Mo...

Страница 4: ...ts Another condition that frequently occurs in a discharged battery is freezing In a deeply discharged battery the electrolyte has a reduced specific gravity and becomes a higher percentage of water t...

Страница 5: ...ourse we ll also fill you in on the complete line of YUASA batteries chargers and accessories About YUASA The first thing you need to know about batteries is YUASA You might say that when it comes to...

Страница 6: ...er Patented Poly Seal Eliminates acid seepage reduces Seal Terminal corrosion extends battery life Case Cover Polypropylene Superior resistance to gasoline oil impact resistant in extreme weather cond...

Страница 7: ...scale A 6 volt battery will have three cells A 12 volt battery six cells HEAT SEALED CASE TO COVER protects against seepage and corrosion bonded unit gives extra strength THRU PARTITION CONSTRUCTION p...

Страница 8: ...arged Inside the cell they re stacked alter nately negative positive negative Insulators or sep arators usually fiberglass or treated paper are placed between the plates to prevent contact Cranking cu...

Страница 9: ...mpact Heat sealed bonded unit construction protects against seepage and corrosion Personal watercraft snowmobiles and ATVs make special demands and YUASA s YuMicron Battery meets them head on The high...

Страница 10: ...VRLA batteries hold voltage longer and need less charging in standby or storage mode High Performance version provides greater cranking power with 12 extra plates per battery For top power less mainte...

Страница 11: ...ive to positive negative to negative Unplug the charger or turn it off before you disconnect the leads that cuts down on the chance of sparks 6 Always wear eye protection protective gloves and protect...

Страница 12: ...ase ensure you have the proper charging voltage Always refer to your service manual Selecting the right battery is an important decision You d be amazed how often the problem with a battery is that it...

Страница 13: ...d sensor at the same time But the sensor s original equipment you say Doesn t matter Being OE doesn t mean it s OK in another man ufacturer s battery In fact OE sensor plugs vary consid erably in leng...

Страница 14: ...a ture Once it s unsealed a battery should be activated charged and installed The plates of an unsealed uncharged battery begin to oxidize That makes it more difficult to charge later We talk more abo...

Страница 15: ...al activity inside the bat tery would come to a standstill It s bad for a battery So is allowing a battery to remain discharged for a prolonged period Recharging becomes hard or impossible The good ne...

Страница 16: ...x Number of Days From100 Charged to 100 Discharged Temperature Lead Antimony Lead Calcium Battery Battery 104 F 100 Days 300 Days 77 F 200 Days 600 Days 32 F 550 Days 950 Days 104 F 77 F 32 F 0 100 20...

Страница 17: ...p for losses from normal starting and self discharge You re going to have to charge the battery more often Maybe every month or so depending on temperature Does the surface the vehicle s parked on or...

Страница 18: ...2 Inspect battery terminals screws clamps and cables for problems breakage corrosion or loose connections Clean the terminals and clamps with a wire brush and coat terminals with no ox grease 3 Inspe...

Страница 19: ...ng ball and calibrated float types or 2 a voltmeter or multimeter which gives DC voltage readings Which is best If you re choosing between two hydrometers opt for the calibrated float type It gives yo...

Страница 20: ...remain in an open circuit condition for at least 1 2 hours LOADED TESTING There are two types of loaded tests for motorcycle batteries You ll need a voltmeter or multi meter Low load test Basically t...

Страница 21: ...rates For most motorcycle and other small engine start ing batteries charge them at 1 10 of the rated ampere hour values in the Yuasa Applications Book see example on page 12 for ratings Battery volt...

Страница 22: ...2 0v 11 9v 0 12 0v or less 11 9v or less 11 8v or less POINTS TO REMEMBER Fully charge battery when new and keep it fully charged Test charging batteries as necessary for overheating water and state o...

Страница 23: ...arge Times Hours Using a Trickle 0 25 Amp Charger 75 13 15 18 23 24 25 50 25 30 35 45 48 50 25 38 45 53 68 71 75 0 50 60 70 90 95 100 Approximate Charge Times Hours Using a 1 Amp Taper Charger 75 6 7...

Страница 24: ...use of 1 continuous dis charging or 2 low electrolyte levels Let s back up just a minute we said earlier that dis charge turns the lead plates into lead sulfate This lead sulfate is actually a crystal...

Страница 25: ...case and buckle the plates which means the battery is permanently damaged A fully charged battery can be stored at sub freezing temperatures with no damage As the chart at right shows it takes 75 F to...

Страница 26: ...rences in activating a sealed VRLA battery Be sure to follow the instructions in this section 2 While Yuasa sealed VRLA batteries dramatically reduce the need for maintenance they do need periodic cha...

Страница 27: ...The positive plate still makes oxygen but instead of being forced out the vent tube it reacts with the charged active material to become water again That s gas recombinant technology That s the magic...

Страница 28: ...acles Don t separate the individual cells Read electrolyte handling instruction and precautions on the label Activation and Installation Save this strip 5 SECTION Sealed VRLA Batteries To Activate a S...

Страница 29: ...approximately 80 charged Place cap strip loosely over the filling holes as shown in drawing above Immediately charge your battery after the stand period to bring it to a full state of charge See Charg...

Страница 30: ...30 minutes after end of charge Therefore to determine the state of charge and the health of the battery measure the open circuit voltage 1 hour after end of charge For a battery that has been in use...

Страница 31: ...p Hour Capacity Rating of the battery Discharge Characteristics Starting the engine is a big part of the battery s job but not all Electrical accessories and safety systems lights and horn need a stab...

Страница 32: ...ne charges Flattering but wrong Forgetting routine charging can mean a one way ticket to the battery graveyard Self discharge Self discharge Characteristics Relation between Storage Period months and...

Страница 33: ...st and most convenient method for error proof charging and battery maintenance These batteries are a sealed VRLA construction which means NEVER REMOVE THE SEALING STRIP AFTER CHARGING IS COMPLETED If...

Страница 34: ...o the sealed VRLA battery to make up the difference Overcharging can warp plates making future charging difficult or impossible Watch charging times carefully or ideally use a Yuasa Automatic Charger...

Страница 35: ...to the table below Criteria Judgement 12 8v or higher Good 12 0 12 8v or lower Charge insufficient Recharge 12 0v or lower Unserviceable Replace Adjust voltage so that current will be at standard amp...

Страница 36: ...ions are discharged positive ions are formed or at which other oxidiz ing reactions occur Antimonial Lead Alloy A commonly used alloy in battery castings The percentage of antimo ny varies from 1 2 t...

Страница 37: ...a constant value For some types of batteries this may involve two rates called a starting and a finishing rate Constant Potential Charge or Constant Voltage Charge A charge that holds the voltage at...

Страница 38: ...of a battery The prescribed voltage reached when the discharge is consid ered complete Finishing Rate The rate of charge in amperes to which charging current is reduced near the end of the charge for...

Страница 39: ...r painted near tops of battery contain ers indicating maximum and minimum electrolyte levels Litharge A yellow red oxide of lead sometimes used in making active material Local Action A battery s loss...

Страница 40: ...nductor that connects the plate group strap to the outside of the cell Pure Lead Pig Lead Rated Capacity Ampere hours of discharge that can be removed from a fully charged cell or battery at a specif...

Страница 41: ...of no use Sulfated A plate or cell whose active materials contain an apprecia ble amount of lead sulfate Sulfation Formation of lead sulfate on a plate or cell as a result of dis charge self discharge...

Страница 42: ...ressure for recombination of oxygen and hydrogen into water Watering Adding water to battery electrolyte to replace loss from elec trolysis and evaporation Watt A unit of electric power equal to a cur...

Страница 43: ...Battery Accessory Lead and Fused Ring Connectors Simple quick connection Can be used with Yuasa s 1 5 Amp and 900 mA chargers for applications ranging from motorcycles automobiles and personal waterc...

Страница 44: ...IN U S A P O Box 14715 Reading PA 19612 4715 Telephone 1 866 431 4784 Fax 610 929 1295 yuasabatteries com TM Tank Sports Inc 10925 Schmidt Rd El Monte CA 91733 www tank sports com 1 866 969 8265 Orde...

Отзывы: